Attenuation and speed of ultrasound in lung.

نویسنده

  • F Dunn
چکیده

An earlier study established that the attenuation of z0 ultrasound in freshly excised dog lung at 1 MHz was unusually high, viz., more than an order of magnitude greater than air and greatly in excess of that exhibited by other soft tissues. • The opportunity to conduct such measurements as a function of frequency has since become available and the following is an initial reporting of this investigation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Ability of Ultrasonic Characterization to Extract the Dose Distribution of MAGIC-f Polymer Gel

Background & Aims: Today, different imaging techniques have been studied in the reading of radiationsensitive polymer gels dosage. Due to limitations of imaging techniques such as magnetic resonance imaging (MRI) and computed tomography (CT), ultrasound techniques are proposed for dose-dependent parameter extraction. In this study, using MAGIC-f (methacrylic and ascorbic acid in gelatin initiat...

متن کامل

اثرغلظت‌های مختلف ژلاتین در دز 36 گری پرتوهای گاما بر پارامترهای فراصوتی ژل پلیمر MAGIC-f

The aim of this study is to evaluate the effect of edible gelatin concentration as a polymerization agent on MAGIC-f polymer gel dose-response sensitivity irradiated by 1.25 MeV energy of cobalt-60. To investigate the dose-dependent polymerization, ultrasonic parameters of propagation speed of sound and broadband ultrasound attenuation coefficient were evaluated. To read-out of the radiation-in...

متن کامل

Attenuation and speed of ultrasound in lung: dependence upon frequency and inflation.

The dependence of the speed of sound and the attenuation coefficient upon exposure frequency, in the range of 1-5 MHz, and upon level of inflation, in the range of mass density 0.35-0.7 g/cm3, are reported. The speed of sound decreases linearly and the attenuation coefficient increases exponentially, for all levels of inflation studied.

متن کامل

Translational Insights on Lung Transplantation: Learning from Immunology

The introduction of ex vivo lung perfusion (EVLP) in the practice of lung transplantation has allowed the reconditioning of the marginal grafts and their conversion into transplantable grafts. In addition, EVLP can provide a platform for the application of various preventive measures to decrease the incidence of post-transplant complications. While the Toronto team targets the attenuation of th...

متن کامل

Mass Attenuation Coefficients of Human Body Organs using MCNPX Monte Carlo Code

Introduction: Investigation of radiation interaction with living organs has always been a thrust area in medical and radiation physics. The investigated results are being used in medical physics for developing improved and sensitive techniques and minimizing radiation exposure. In this study, mass attenuation coefficients of different human organs and biological materials such as adipose, blood...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 56 5  شماره 

صفحات  -

تاریخ انتشار 1974