Open-Coil Retraction Spring
نویسنده
چکیده
Sliding mechanic has become a popular method for space closure with developments in preadjusted edgewise appliance. Furthermore, various space closing auxiliaries have been developed and evaluated extensively for their clinical efficiency. Their effectiveness enhanced with optimum force magnitude and low-load deflection rate (LDR)/force decay. With the advent of NiTi springs in orthodontics, LDRs have been markedly reduced. For use of NiTi, clinician has to depend upon prefabricated closed coil springs. "Open Coil Retraction Spring (OCRS)" is developed utilizing NiTi open-coil spring for orthodontic space closure. This paper describes fabrication and clinical application of OCRS which have number of advantages. It sustains low LDR with optimum force magnitude. Its design is adjustable for desired length and force level. It is fail-safe for both activation and deactivation (i.e., it cannot be over activated, and decompression limit of open coil is also controlled by the operator, resp.). A possibility to offset the OCRS away from mucosa helps to reduce its soft-tissue impingement.
منابع مشابه
Evaluating the Amount of Tooth Movement and Root Resorption during Canine Retraction with Friction versus Frictionless Mechanics Using Cone Beam Computed Tomography
BACKGROUND The current study was carried out to compare the amount of tooth movement during canine retraction comparing two different retraction mechanics; friction mechanics represented by a NiTi closed coil spring versus frictionless mechanics represented by T - loop, and their effect on root resorption using Cone Beam Computed Tomography (CBCT). METHOD Ten patients were selected in a split...
متن کاملPentraxin-3 Levels in Gingival Crevicular Fluid during Canine Retraction with NiTi Coil Spring and Active Tieback
Aim: Orthodontic treatment is routinely carried out in patients with the purpose of correcting various forms of dental malocclusions. Retraction of the canines can be achieved either individually or along with incisor. Pentraxin-3 (PTX-3) is regarded as the true independent indicator of disease activity. Hence, we undertook the present study to assess and compare the level of PTX-3 in patients ...
متن کاملThe retraction of upper incisors with the PG retraction system.
The aim of this study was to evaluate the effect on the dentoalveolar structures of the application of PG springs for retraction of upper incisors and to compare the outcome with the effect of a closed coil spring retraction system. Thirty-six subjects with Angle Class I or Class II malocclusions were selected for the study. Each subject had the two upper first premolars extracted and presented...
متن کاملSpring coil retraction in coil occlusion of persistent ductus arteriosus.
AIMS To present the short and intermediate term results of coil occlusion of persistent ductus arteriosus and the results of radiographic measurements of spring coils implanted to treat patent ducts. PATIENTS 22 children underwent coil occlusion. Their ages ranged from 2 years 9 months to 12 years 10 months (mean (SD) age, 6.5 (3.6) years). The duct diameter ranged from 1.0 to 3.5 mm at the n...
متن کاملA prospective comparative study between differential moments and miniscrews in anchorage control.
The purpose of this study was to measure the efficacy of anchorage control between differential moments mechanics and temporary anchorage devices in a clinical trial. Forty-six patients requiring extraction of maxillary first premolars were allocated into 2 treatment groups. The differential moments group (G1) received a nickel titanium (NiTi) intrusion arch and a 150g NiTi closing coil spring ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2011 شماره
صفحات -
تاریخ انتشار 2011