Validation of a NaI(Tl) detector’s model developed with MCNP-X code

نویسندگان

  • C. M. Salgado
  • R. Schirru
چکیده

The Monte Carlo method was used to calculate the photon detection efficiency and energy resolution curves for a 1.500 100 NaI(Tl) scintillator detector (crystal þ housing þ photomultiplier tube material equivalent) exposed to gamma rays in the energy range from 20 keV to 662 keV. This work aims to design a precise computational model, based in Monte Carlo simulation, which can be used in practical application. The energy resolution curve was used to improve the response of the mathematical simulation of the detector. The detector was modeled with the MCNP-X code and the results were compared to experimental photopeak efficiency measurements of radiation sources. The results showed good agreement with the experimental data. 2012 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration with MCNP of NaI detector for the determination of natural radioactivity levels in the field.

In view of assessing natural radioactivity with on-site quantitative gamma spectrometry, efficiency calibration of NaI(Tl) detectors is investigated. A calibration based on Monte Carlo simulation of detector response is proposed, to render reliable quantitative analysis practicable in field campaigns. The method is developed with reference to contact geometry, in which measurements are taken pl...

متن کامل

مقایسه‌ی آشکارسازهای سوسوزن :Ce3LaBr و NaI(Tl) با استفاده از داده‌های تجربی و شبیه‌سازی باکد MCNP 4C

آشکارسازهای :Ce3LaBr و NaI(Tl) دو نوع آشکارساز سوسوزن معدنی هستند که به دلیل مقدار بالای نور خروجی‌اشان در مقایسه با سوسوزن‌های آلی و تقریباً سایر سوسوزن‌های معدنی مورد توجه هستند. در این کار پژوهشی نتایج تجربی اندازه‌گیری و شمارش چشمه‌های پرتوزا با و بدون حفاظ با نتایج شبیه‌سازی برای بلورهای هر دو آشکارساز با کد MCNP 4C مقایسه شد. نتایج به دست آمده از اندازه‌گیری چشمه‌های پرتوزای صفحه‌ای به وسی...

متن کامل

Organ and effective dose arising from conventional diagnostic X-ray examinations by Monte Carlo simulation (MCNP-4C Code)

 ABSTRACTBackground: Monte Carlo simulation has been used by many researchers to calculate organ and effective dose of patients arising from conventional X-ray examinations. In this study the radiation transport code, MCNP-4C, has been used to perform Monte Carlo simulations to estimate radiation dose delivered to different organs in conventional X-ray examinations.Material and Methods: In this...

متن کامل

X-ray spectra calculation for different target-filter of mammograms using MCNP Code

 ABSTRACTBackground: An electron beam generated X-ray spectrum consists of characteristic X-ray and continuous bermsstrahlung. The aim of this research is calculating and comparing X-ray spectra for different target filter of mammograms. Materials and Methods: Monte Carlo is a very powerful tool to simulate a series of different target-filter assembly in order to calculate the X-ray spectra. MC...

متن کامل

Calibration curves for on-line leakage detection using radiotracer injection method

One of the most important requirements for industrial pipelines is the leakage detection. In this paper, detection of leak and determination of its amount using radioactive tracer injection method has been simulated by Monte Carlo MCNP code. The detector array included two NaI (Tl) detectors which were located before and after the considered position, measure emitted gamma from radioactive trac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012