Rapid screening for bacteriuria using a particle counter, pulse-height analyser, and computer.

نویسندگان

  • M K Alexander
  • M S Khan
  • C S Dow
چکیده

A system for the rapid screening of urines for the presence of bacteriuria has been devised using a Coulter Counter Model ZBI linked to a multichannel pulse-height analyser (Coulter "Channelyser") with computer analysis of the output. In a series of 215 urines containing growth of a single pathogen of more than 100 x 10(6)/l (greater than 100 000/ml) satisfactory level of sensitivity (99.1%) was obtained using only two different amplification settings by means of a brief treatment (5-10 seconds) of the undiluted specimen with low intensity ultrasound; 85-90% of mixed growths of 10 x 10(6)/l (greater than 10 000/ml) were detected. Sonication did not improve the results in this group. Specimens showing abnormal cyturia of more than 10 x 10(6)/l (greater than 10 000/ml) but no growth on culture were positive in 33% of cases without the use of ultrasound but in 72% after sonication.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mitochondria of Tetrahymena pyriformis: enumeration and sizing of isolated organelles using a Coulter Counter and pulse-height analyser.

An electronic particle counter (Coulter Counter ZBI) and pulse-height analyser (Channelyzer C1000) have been used to measure numbers and sizes of mitochondria isolated from the ciliated protozoon Tetrahymena pyriformis. Differential centrifugation of disrupted organisms, followed by single-step sub-fractionation of the mitochondrial fraction on sucrose gradients yielded a population of organell...

متن کامل

Particle size distribution analysis for the rapid detection of microbial infection of urine.

The accuracy and practicality of particle size distribution analysis for rapid screening of urine specimens are assessed. Six hundred urines were subjected simultaneously to routine bacteriological examinations and particle size distribution analysis using a Coulter Counter (ZBI) linked to a C1000 Channelyzer. There was complete agreement in the results of 593 (98.8%) specimens. Characteristic ...

متن کامل

Investigation for background prevalence of Brucella agglutinins among blood donors.

(w ww .m ed kn ow .co m) . The results are shown in the Table. The exponential character of turbidity increase was less sensitive yet a more speciÞ c screening criterion, thus it is suitable for preliminary conÞ rmation of signiÞ cant bacteriuria. The non-speciÞ ed turbidity increase estimation2 has a high negative predictive value and is suitable (just like the biochemical screening)1,3 for pr...

متن کامل

Evaluation of rapid urine screening tests to detect asymptomatic bacteriuria in pregnancy.

In order to compare the performance of leukocyte esterase and nitrite urine dipstick tests with enhanced urinalysis (uncentrifuged urine white blood cell count/mm(3) plus Gram stain) in detecting asymptomatic bacteriuria in obstetric patients, clean-catch midstream urine specimens were collected from 250 consecutive asymptomatic pregnant women. Ten of the women (4.0%) showed urine culture resul...

متن کامل

Improved measurement of erythrocyte volume distribution by aperture-counter signal analysis.

In aperture counters, particles in fluid suspension flow through a small orifice or aperture, causing a change in the electrical resistance of the aperture. This change is sensed by an external electronic circuit and translated into a voltage pulse, the signal height of which is proportional to the volume of the particle in the aperture. These signal pulses are collated into a spectrum of pulse...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 34 2  شماره 

صفحات  -

تاریخ انتشار 1981