A comparison of visual outcome and rotational stability of two types of toric implantable collamer lenses (TICL) : V4 versus V4c
نویسندگان
چکیده
PURPOSE To compare the efficacy and rotational stability after implantation of two types of toric implantable collamer lenses (Toric ICL™(TICL);V4 and V4c, STAAR Surgical Co.). STUDY DESIGN Retrospective case series. METHODS This retrospective study evaluated total 48 eyes of 48 patients who underwent the implantation with V4 and V4c TICL with a central hole; A twenty-four eyes of 24 patients with V4 TICL and 24 eyes of 24 patients with V4c TICL with a central hole. Visual acuity, manifest refraction, and intraocular pressure were evaluated before and after surgery. Rotational stability (disparity between the intended axis and achieved axis) was assessed in both groups using digital anterior segment photographs, and vector analysis was also performed. RESULTS Uncorrected visual acuity improved in both groups without significant difference (P = .111). There were no statistical differences between two groups in postoperative SE and cylindrical errors (P = .067 and .384, respectively). The mean value of rotation was 4.17±3.31° and 3.39±2.36° in the V4 and V4c TICL groups, respectively without significant difference (P = .364). Vector analysis of astigmatic correction showed no significant diffrence between two groups. CONCLUSION V4 and V4c TICL have similar efficacy with regard to visual acuity and refractive outcomes and rotational stability.
منابع مشابه
Pseudophakic ametropia management with toric implantable collamer lens with a central hole (case report)
BACKGROUND To report the clinical outcomes of correcting pseudophakic ametropia using toric implantable collamer lens with a 360 um central hole (TICL V4c). CASE PRESENTATION The right eye of a 22-year-old male patient developed high myopia after unilateral phacoemulsification and intraocular lens (IOL) implantation following traumatic cataract 16 years ago. The manifest refraction was -11.50...
متن کاملImplantable collamer lens V4b and V4c for correction of high myopia
PURPOSE To evaluate the visual outcome and intraocular pressure changes after Visian Implantable Collamer Lens (ICL) implantation V4b and V4c (with central hole) for correction of high myopia. METHODS A prospective, consecutive, interventional comparative case series of V4b and V4c ICL implantation was done in high myopic patients who were unsuitable for laser vision. The main outcome measure...
متن کاملComparison of Implantable Collamer Lens Visian ICL V4 and ICL V4c for high myopia
The aim of this study was to investigate the visual quality of the 2 kinds of intraocular lens: Visian implantable collamer lens (ICL) V4 and Visian ICL V4c implantations for high myopia.Twenty cases (20 eyes) with high myopia who received Visian ICL V4 implantation and 18 cases (18 eyes) with high myopia who received Visian ICL V4c implantation in our hospital from April 1, 2014 to November 31...
متن کاملStability of axis and patient satisfaction after toric implantable collamer lens implantation for myopic astigmatism
OBJECTIVES To assess the stability of axis and patient satisfaction after toric visian implantable collamer lens (TICL) implantation for moderate to high myopic astigmatism. METHODS Total 33 eyes of 21 consecutive patients who underwent implantation of TICL for the correction of moderate to high myopic astigmatism were recorded and a minimum follow-up of six months was performed. The deviatio...
متن کاملSpontaneous Rotation of a Toric Implantable Collamer Lens
We present a case of toric implantable collamer lens (TICL) spontaneous rotation in a patient with myopic astigmatism. A 23-year-old female underwent TICL implantation. Preoperative uncorrected visual acuity (UCVA) was 20/800 and 20/1200, respectively, with -7.75 -4.25 × 0° and -8.25 -5.25 × 180°. The left eye achieved an UCVA of 20/30. After 3 months of successful implantation of TICL in the l...
متن کامل