Complications of volar plating of distal radius fractures.

نویسندگان

  • Michele Rampoldi
  • Salvatore Marsico
چکیده

Open reduction and internal fixation has been shown to be effective in the treatment of unstable distal radius fractures. When a dorsal approach is used, extensor tendons rupture or irritation are frequent and well known complications. Complications associated with volar plate fixation have not been studied to the same extent. In this study a homogenous series of 90 patients treated by volar plate fixation were retrospectively evaluated, focusing on the complications observed. The overall rate of complications was 8% (7 cases). Tendon rupture or irritation of extensor (3 cases) and flexor tendons (2 cases) were the complications most frequently seen. All but one were clearly related to direct attritional damage of the tendon caused by the prominent edge of the plate or by protruding screw tips. Loss of reduction requiring repeat internal fixation was observed in one marginal shear fracture involving the lunate facet fragment. One patient had a carpal tunnel release owing to median nerve irritation. In this study, volar plate fixation appeared as a safe procedure in the management of unstable distal radius fractures, with a low rate of complications. Accurate placement of the plate and exact measurement of the screws may further minimize the incidence of complications. When radiographs reveal conditions that may predispose to tendon attritional lesions (prominent edge of the plate, dorsal protrusion of the screw tips) we strongly recommend early removal of the fixation device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Complications and Plate Removal Surgeries after Performing Volar Plating of Unstable Distal Radius Fractures

Complications have often been reported in the literature after distal radius fractures treated conservatively or operatively [1-3]. Previously, the main indication for volar plating was a volar Barton or Smith fracture, but now volar locking plates are the most commonly used treatment for unstable distal radius fractures and during the last decade this method has become increasingly popular [4]...

متن کامل

Extensor indicis proprius and extensor digitorum communis rupture after volar locked plating of the distal radius--a case report.

Distal radius fractures are among the most commonly encountered fractures in the extremities. Volar plating of distal radius fracture has gained popularity in recent years with the introduction of the locked plating system. Complications of volar plating include extensor and flexor tendon rupture. Here we present a case report of an extensor indicis proprius and extensor digitorum communis to i...

متن کامل

Volar Distal Radius Anatomy Applied to the Treatment of Distal Radius Fracture.

Volar locking plate (VLP) fixation has become the standard surgical treatment for distal radius fractures. However, flexor tendon rupture is one of the major complications following volar plating. This detailed review on the anatomy and morphology of the volar distal radius might facilitate appropriate placement of the volar plate and thereby avoid flexor tendon rupture. We introduce safe and s...

متن کامل

Volar Plating as a Treatment for Distal Radius Fractures

Locked volar plating is the most common surgical procedure to address distal radius fractures. The extended flexor carpi radialis (FCR) approach continues to be an excellent method for visualizing distal radius fractures and applying a volar plate. (See Video 1, Supplemental Digital Content 1, which discusses distal radial fracture advancements and possible complications. This video is availabl...

متن کامل

Locked volar plating for complex distal radius fractures: Patient reported outcomes and satisfaction

BACKGROUND Distal radius fractures are common. The increasing prevalence of osteoporosis contributes to frequently complex articular injuries sustained even after low energy falls. The best method of treating complex type C distal radius fractures is debated. Locked volar plating and external fixation are both widely used with good reported results. Measures of success are traditionally based o...

متن کامل

Various volar shapes of the distal radius and its implications on volar plate osteosynthesis

Volar plate fi xation with use of either a locking plate or a neutralization plate has become increasingly popular among surgeons for the treatment of dorsally comminuted distal radial fractures. When doing volar plating of radius fractures, we observed a considerable variation in the morphology of the distal radius. Research in the literature reveals rare information about the anatomic variati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 73 6  شماره 

صفحات  -

تاریخ انتشار 2007