An oversampling system for ECG acquisition

نویسنده

  • Yu Zhou
چکیده

Traditional ECG acquisition system lacks for flexibility. To improve the flexibility of ECG acquisition system and the signal-to-noise ratio of ECG, a new ECG acquisition system was designed based on DAQ card and Labview and oversampling was implemented in Labview. And analog signal conditioning circuit was improved on. The result indicated that the system could detect ECG signal accurately with high signal-to-noise ratio and the signal processing methods could be adjusted easily. So the new system can satisfy many kinds of ECG acquisition. It is a flexible experiment platform for exploring new ECG acquisition methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Oversampling Limits for Binary Offset Carrier Modulation for the Acquisition of Galileo Signals

Code and frequency acquisition are important stages of today’s satellite systems, such as the European system Galileo. Newly proposed modulation types, such as Binary Offset Carrier (BOC) modulation, have triggered new challenges in the acquisition process. The features and properties of BOC-modulated code sequences are still not wellunderstood in the context of fast acquisition algorithms. Mor...

متن کامل

A Multichannel Data Acquisition System Based on Parallel Processor Architectures

For research purposes on helicopter rotor acoustics a large data acquisition system called TEDAS (Transputer based Expandable Data Acquisition System) has been developed. The key features of this system are: unlimited expandability and sum data rate, local storage of data during opration, very simple analog anti aliasing filtering due to extensive digital filtering, and integrated computational...

متن کامل

Very Low Power Sigma Delta Modulator for Biomedical Applications

This paper discusses the design of picowatt power Sigma-delta modulator with genetic algorithm (GA) based oversampling technology. This Sigma-delta modulator design is paid special attention to its low power application of portable electronic system in digitizing biomedical signals such as Electro-cardiogram (ECG), Electroencephalogram (EEG) etc. [1]. A high performance, low power second order ...

متن کامل

Evaluation of 4D CT acquisition methods designed to reduce artifacts

Four-dimensional computed tomography (4D CT) is used to account for respiratory motion in radiation treatment planning, but artifacts resulting from the acquisition and postprocessing limit its accuracy. We investigated the efficacy of three experimental 4D CT acquisition methods to reduce artifacts in a prospective institutional review board approved study. Eighteen thoracic patients scheduled...

متن کامل

Non-data aided timing acquisition of ultra-wideband transmissions using cyclostationarity

Low-complexity rapid timing acquisition constitutes a major challenge in realizing the high potential that ultra-wideband (UWB) wireless technology promises for indoor communications. We derive and test two such timing acquisition algorithms which capitalize on the cyclostationarity that is naturally present in UWB transmissions. Our novel schemes are blind, they do not require multiple antenna...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009