Dosimetric effects of swelling or shrinking tissue during helical tomotherapy breast irradiation. A phantom study

نویسندگان

  • Rudolf Klepper
  • Sebastian Höfel
  • Ulrike Botha
  • Peter Köhler
  • Felix Zwicker
چکیده

During radiation therapy of the female breast, the actual target volume compared to the planning target volume may change due to swelling or shrinking of the tissue. Under- or overdosage is to be expected, especially when performing IMRT or tomotherapy techniques. The objective of this study is to develop a model-based quantification of these dose effects, with a particular focus on the changes in the surface dose. A cylindrical phantom was used as an artificial surrogate of the human torso. By adding and removing Superflab layers of various thicknesses, both radial breast swelling and shrinking could be simulated. The effects on dose distribution were evaluated using film dosimetry. The results were compared to dose calculations. To estimate the true surface doses, we subtracted the influence of the film material on air measurements. During a swelling of 5, 10, and 15 mm, the planning target volume was consistently underdosed by 2%, 5%, and 7% of the prescribed dose, respectively. Swelling led to reduced dose values of up to 72%, 55%, and 50% at the outer edge of the actual target volume. The measured surface dose decreased successively from 31% to 23%. During shrinking, the dose in the planning target volume increased successively from 100% to 106%. The measured surface doses increased from 29% to 36%. The calculated dose values agreed with the measured values within error limits. During radiotherapy of the female breast, new planning appears to be essential for radial tissue swelling of 5 mm or more because of severe underdosing. Shrinking leads to moderate overdosing and an increased surface dose. In addition, caution is advised when removing bolus material with respect to the planned situation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy.

BACKGROUND Accelerated partial breast irradiation (APBI) is a new breast treatment modality aiming to reduce treatment time using hypo fractionation. Compared to conventional whole breast irradiation that takes 5 to 6 weeks, APBI is reported to induce worse cosmetic outcomes both when using three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT). These late...

متن کامل

Breast Conserving Treatment for Breast Cancer: Dosimetric Comparison of Sequential versus Simultaneous Integrated Photon Boost

BACKGROUND Breast conserving surgery followed by whole breast irradiation is widely accepted as standard of care for early breast cancer. Addition of a boost dose to the initial tumor area further reduces local recurrences. We investigated the dosimetric benefits of a simultaneously integrated boost (SIB) compared to a sequential boost to hypofractionate the boost volume, while maintaining norm...

متن کامل

A treatment planning study comparing whole breast radiation therapy against conformal, IMRT and tomotherapy for accelerated partial breast irradiation.

PURPOSE AND BACKGROUND Conventional early breast cancer treatment consists of a lumpectomy followed by whole breast radiation therapy. Accelerated partial breast irradiation (APBI) is an investigational approach to post-lumpectomy radiation for early breast cancer. The purpose of this study is to compare four external beam APBI techniques, including tomotherapy, with conventional whole breast i...

متن کامل

Fast, simple, and informative patient-specific dose verification method for intensity modulated total marrow irradiation with helical tomotherapy

BACKGROUND Patient-specific dose verification for treatment planning in helical tomotherapy is routinely performed using a homogeneous virtual water cylindrical phantom of 30 cm diameter and 18 cm length (Cheese phantom). Because of this small length, treatment with total marrow irradiation (TMI) requires multiple deliveries of the dose verification procedures to cover a wide range of the targe...

متن کامل

Once Daily Accelerated Partial Breast Irradiation: Preliminary Results with Helical Tomotherapy®.

BACKGROUND Accelerated partial breast irradiation (APBI) is becoming an option for patients with low-risk breast cancer. The current practice is 38.5 Gy in 10 fractions b.i.d. over 5 days. This fractionation has a higher bioequivalent dose compared to the standard schedule. We report on preliminary results of once-daily APBI in patients treated with TomoTherapy®. PATIENTS AND METHODS Patients...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014