Comparison of two single-image phase-retrieval algorithms for in-line x-ray phase-contrast imaging.
نویسندگان
چکیده
The attenuation of x-rays in a material forms the basis of x-ray radiography and tomography. By measuring the transmission of the x-rays over a large amount of raypaths, the three-dimensional (3D) distribution of the x-ray linear attenuation coefficient can be reconstructed in a 3D volume. In x-ray microtomography (μCT), however, the x-ray refraction yields a significant signal in the transmission image and the 3D distribution of the refractive index can be reconstructed in a 3D volume. To do so, several methods exist, on both a hardware and software level. In this paper, we compare two similar software methods, the modified Bronnikov algorithm and the simultaneous phase-and-amplitude retrieval. The first method assumes a pure phase object, whereas the latter assumes a homogeneous object. Although these assumptions seem very restrictive, both methods have proven to yield good results on experimental data.
منابع مشابه
Theory and algorithms for phase-contrast CT
Applications of x-ray computed tomography (CT) vary from medical and biological imaging to material research and industrial inspection. We briefly discuss the state of the art in conventional absorption-based CT and make a link to a new imaging technique: phase-contrast CT. This technique can be implemented at third generation synchrotron radiation sources or by using a microfocus x-ray tube. U...
متن کاملPhase Contrast Imaging Using a Single Picosecond X-ray Pulse of the Inverse Compton Source at the Bnl Accelerator Test Facility∗
Inverse Compton scattering (ICS) X-ray sources are of current interest due to their novel features that enable new methods in medical and biological imaging. As a compelling example of such a possibility, we present an experimental demonstration of single shot inline phase contrast imaging using the ICS source located at the BNL Accelerator Test Facility. The phase contrast effect is clearly ob...
متن کاملIn-line Phase-sensitive X-ray Imaging
10.2 Physics Principles of In-line X-ray Phase-contrast Imaging......................................145 10.2.1 Attenuation, Phase Shift, and Optical Transmission ...................................145 10.2.2 System Configuration of In-line Phase-contrast Imaging............................145 10.2.3 Theoretical Framework of In-line Phase-contrast Imaging with Ideal Imaging Systems ...............
متن کاملQuantitative evaluation of a single-distance phase-retrieval method applied on in-line phase-contrast images of a mouse lung
Propagation-based X-ray phase-contrast computed tomography (PBI) has already proven its potential in a great variety of soft-tissue-related applications including lung imaging. However, the strong edge enhancement, caused by the phase effects, often hampers image segmentation and therefore the quantitative analysis of data sets. Here, the benefits of applying single-distance phase retrieval pri...
متن کاملSingle-distance phase retrieval at large phase shifts.
For coherent X-ray imaging of pure phase objects we study the reliability of linear relations in phase-retrieval algorithms based on a single intensity map after free-space propagation. For large phase changes and/or large propagation distances we propose two venues of working beyond linearity: Projection onto an effective, linear and local model in Fourier space and expansion of intensity cont...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the Optical Society of America. A, Optics, image science, and vision
دوره 29 12 شماره
صفحات -
تاریخ انتشار 2012