Quantitative Determination of High Charge Density Polyanion Contaminants in Biomedical Heparin Preparations Using Potentiometric Polyanion Sensors.

نویسندگان

  • Lin Wang
  • Mark E Meyerhoff
چکیده

Quantification of oversulfated chondroitin sulfate (OSCS) in biomedical heparin preparations is achieved using a recently described potentiometric polyanion sensor-based approach operated in a kinetic mode of analysis. This is accomplished by adjusting the concentration of the test sample to a range where the OSCS level is low enough for the sensor not to achieve a full and rapid equilibrium phase boundary potential change at the membrane/sample interface upon exposure to the heparin sample. Using this method, the OSCS wt% determined within heparin samples containing OSCS are shown to be in good agreement with those determined by an accepted NMR method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Insufficient accuracy and specificity of polyanion precipitation methods for quantifying low-density lipoproteins.

Recently, polyanion precipitation assays for low-density lipoprotein (LDL)-cholesterol have been found to underestimate their analyte in normolipidemic samples (Siekmeier et al., Clin Chim Acta 1988;177:221-30). Therefore, accuracy, specificity, and interference by nonesterified fatty acids have been studied for three precipitants (obtained by heparin, dextran sulfate, or polyvinyl sulfate prec...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Heparin versus DNA: Chiral Preferences in Polyanion Binding to Self-Assembled Multivalent (SAMul) Nanostructures.

This communication presents simple cationic self-assembling multivalent (SAMul) first generation dendrons based on L or D lysine, which form identical nanoscale assemblies in terms of dimensions and charge densities but toward which DNA and heparin exhibit different chiral binding preferences. However, higher generation dendrons with larger hydrophilic head groups are bound identically by these...

متن کامل

Nature of the interaction between low-density lipoproteins and polyanions and metal ions, as exemplified by heparin and Ca2+.

I examined the effect of lipid concentration on the interaction of the very-low density and low-density lipoproteins in serum with heparin and calcium. A precipitate forms when partly delipidated serum is subjected to the polyanion-metal ion system. Although this precipitate is less turbid than the complexed lipoprotein-polyanion-metal ion in undelipidated serum, the two precipitates contain i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Electroanalysis

دوره 22 1  شماره 

صفحات  -

تاریخ انتشار 2010