Carbon-ion pencil beam scanning for thoracic treatment – initiation report and dose metrics evaluation
نویسندگان
چکیده
Carbon-ion beam scanning has not previously been used for moving tumor treatments. We have commenced respiratory-gated carbon-ion radiotherapy (CIRT) in the thoracic and abdominal regions under free-breathing conditions as a clinical trial. This study aimed to investigate this treatment in the lungs in comparison with passive scattering CIRT. Five patients had thoracic tumors treated with carbon-ion scanned beams using respiratory gating. We analyzed the actual treatments and calculated passive scattering treatment plans based on the same planning CT. We evaluated tumor size until 3 months post treatment and each treatment plan regarding dose delivered to 95% of the clinical target volume (CTV-D95), mean lung dose, percentage of lung receiving at least 5 Gy (RBE) (Lung-V5), Lung-V10, Lung-V20, heart maximum dose (Dmax), esophagus Dmax, cord Dmax and skin Dmax. Obvious tumor deterioration was not observed up to 3 months post treatment. The dose evaluation metrics were similar item by item between respiratory-gated scanned CIRT and passive scattering CIRT. In conclusion, scanned beam CIRT provided treatments equivalent to passive scattering CIRT for thoracic tumors. Increased sample numbers and longer-term observation are needed.
منابع مشابه
Beam Monitors of Nirs Fast Scanning System for Particle Therapy
At National Institute of Radiological Sciences (NIRS), more than 6500 patients have been successfully treated by carbon-ion beams since 1994. The successful results of treatments have led us to construct a new treatment facility equipped with three-dimensional pencil beam scanning irradiation system. The commissioning of NIRS fast scanning system installed into the new facility was started in S...
متن کاملMonte Carlo computation of dose deposited by carbon ions in radiation therapy
Background: High-velocity carbon ion beams represent the most advanced tool for radiotherapy of deep-seated tumors. Currently, the superiority of carbon ion therapy is more prominent on lung cancer or hepatomas. Materials and Methods: The data for lateral straggling and projected range of monoenergetic 290 MeV/u (3.48 GeV) carbon ions in muscle tissue were obtained from the stopping and range o...
متن کاملEvaluation of dose distribution of 12C ion beam in radiotherapy by FLUKA as a Monte Carlo simulation Code
Introduction: Nowadays, the use of heavy ion beams in cancer therapy have been developed worldwide. Materials and Methods: It requires accurate understanding of the complex processes of ion interaction with matter, as it is the calculation the relative dose & range of these ions in matter. In the present study we used FLUKA as a numerical Monte Carlo simula...
متن کاملIba Proton Pencil Beam Scanning: an Innovative Solution for Cancer Treatment
Particles are used in medical application for cancer treatment. Radiotherapy aims to deliver a high dose in a well-defined target volume while sparing the healthy surrounding tissues. Compared to the conventional radiotherapy (X-ray), protons show superior clinical performances thanks to their inherent depth dose characteristic (Bragg peak). In proton therapy, several techniques can be used to ...
متن کاملMonte Carlo-based parametrization of the lateral dose spread for clinical treatment planning of scanned proton and carbon ion beams
Ion beam therapy using state-of-the-art pencil-beam scanning offers unprecedented tumour-dose conformality with superior sparing of healthy tissue and critical organs compared to conventional radiation modalities for external treatment of deep-seated tumours. For inverse plan optimization, the commonly employed analytical treatment-planning systems (TPSs) have to meet reasonable compromises in ...
متن کامل