A multifunctional microfluidic droplet-array chip for analysis by electrospray ionization mass spectrometry.

نویسندگان

  • Yuan Su
  • Ying Zhu
  • Qun Fang
چکیده

This paper describes a multifunctional semi-closed droplet-array chip coupled with electrospray ionization mass spectrometry (ESI-MS) detection for multiple sample pretreatment and analysis. A novel interfacing method for coupling droplet system with ESI-MS was proposed using a sampling probe-two-dimensional (2D) droplet-array strategy. The 2D droplet-array system was composed of an 8 × 8 microwell array chip for droplet storage and a layer of oil covering the droplets served as a "virtual wall" to avoid droplet evaporation or cross-contamination. An L-shaped capillary was adopted as the interface of the droplet array and ESI-MS, using its inlet end as a sampling probe for droplets and its outlet with a tip size of ~20 μm as an electrospray emitter, without the need for any droplet extraction device. The droplet analysis was performed by moving the droplet-array chip to allow the capillary sampling probe to sequentially enter into the droplets through the oil and introduce the sample solution into the capillary emitter for MS detection. The MS analysis time for each droplet sample was 40 s with a sample consumption of ca. 13 nL. A good repeatability of 5.7% (RSD, n = 9) was obtained for 10(-6) M reserpine droplet analysis. The uses of the semi-closed 2D droplet array and off-line interfacing mode provide the system with the substantial flexibility and controllability in droplet indexing, multi-step manipulating, and on-demand sampling for MS analysis. We applied the present system in multi-step pretreatment and identification of small amounts of proteomic samples of myoglobin and cytochrome C, including in-droplet protein reduction, alkylation, digestion, and purification based on solid-phase extraction, matrix modification, sample droplet introduction under flow injection mode, and ESI-MS detection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proteolysis in microfluidic droplets: an approach to interface protein separation and peptide mass spectrometry.

A versatile microreactor protocol based on microfluidic droplets has been developed for on-line protein digestion. Proteins separated by liquid chromatography are fractionated in water-in-oil droplets and digested in sequence. The microfluidic reactor acts also as an electrospray ionization emitter for mass spectrometry analysis of the peptides produced in the individual droplets. Each droplet ...

متن کامل

Sensitive, high throughput detection of proteins in individual, surfactant-stabilized picoliter droplets using nanoelectrospray ionization mass spectrometry.

Droplet-based fluidics is emerging as a powerful platform for single cell analysis, directed evolution of enzymes, and high throughput screening studies. Due to the small amounts of compound compartmentalized in each droplet, detection has been primarily by fluorescence. To extend the range of experiments that can be carried out in droplets, we have developed the use of electrospray ionization ...

متن کامل

Droplet Analysis with Electrospray Ionization Mass Spec- Trometry Using an Integrated Glass Microchip

ABSTRACT We describe an integrated microchip for droplet analysis with electrospray ionization mass spectrometry (ESI-MS). The chip integrated multiple modules of droplet generator, droplet extraction interface, and monolithic ESI-emitter. A novel droplet extraction interface based on a hydrophilic tongue structure was developed to transfer droplet from segmented phase to aqueous phase with hig...

متن کامل

Chip-based microfluidic devices coupled with electrospray ionization-mass spectrometry.

We present the current status of the development of microfluidic devices fabricated on different substrates for coupling with electrospray ionization-mass spectrometry (ESI-MS). Until now, much success has been gained in fabricating the ESI chips, which show better performances due to miniaturization when compared with traditional methods. Integration of multiple steps for sample preparation an...

متن کامل

Bioaffinity Mass Spectrometry Screening Using Droplet-Based Microfluidics

Bioaffinity mass spectrometry screening is a novel approach using non-denaturing electrospray ionization (ESI) mass spectrometry (MS) in identifying drug leads. This screening technique can detect and preserve noncovalent protein-active drug ligand complexes under different physiological conditions. Although there are many successful screening campaigns employing this technique, the big challen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 13 10  شماره 

صفحات  -

تاریخ انتشار 2013