Alcohol Caps or Alcohol Swabs With and Without Chlorhexidine: An In Vitro Study of 648 Episodes of Intravenous Device Needleless Connector Decontamination.

نویسندگان

  • Julie M Flynn
  • Claire M Rickard
  • Samantha Keogh
  • Li Zhang
چکیده

The incidence of central venous access device (CVAD)–associated bloodstream infection (CABSI) has been reported to be as high as 21%. Inadequate needleless connector decontamination can result in microbial contamination of the CVAD internal lumen, resulting in device colonization and CABSI. Guidelines vary in recommendations for antiseptic type and duration of application to needleless connectors. Scrubbing needleless connectors with chlorhexidine in alcohol swabs is recommended by some guidelines to prevent infection. However, lack of consistent needleless connector decontamination prior to use may negate the effectiveness of this approach. There is a need to define the most effective needleless connector decontamination techniques, including the antiseptic type and the duration of application. In this study, we investigated the comparative efficacy of 3 needleless connector decontamination methods and 3 connector types with different durations of application to prevent microbial contamination. In this microbial in vitro study, we used the following types of needleless connectors: SmartSite (CareFusion, Becton Dickinson, Franklin Lakes, NJ; n= 216), Safeflow (B.Braun, Melsungen, Germany; n= 216), andMaxPlus Clear (CareFusion, Becton Dickinson; n= 216). A total of 648 connector decontamination procedures were performed for this study; 3 experiments per connector type were performed to ensure valid results. Staphylococcus aureus, S. epidermidis, Pseudomonas aeruginosa, and Candida albicans were used as test organisms. For half of the experiments (n= 324 connectors), needleless connectors were precoated with sterile human serum, which remained in situ for 1 hour under static conditions in a class II biological safety cabinet, prior to exposure to microbial inoculum. Human serum (Sigma-Aldrich) was filter sterilized (0.2μm) before use. The overnight broth culture was adjusted to an OD600 (optical density of a sample measured at 600 nm) of 0.12 and diluted to 1:200 (final concentration 0.5×10) before application to each needleless connector. These parameters were chosen as a possible clinically reflective levels rather higher concentrations used in other studies. Following air drying, the inoculated needleless connectors were disinfected with 1 of the following 3 items: 70% isopropyl alcohol swabs (IPA swabs; Reynard Health Supplies, Havelock North, Hawkes Bay, New Zealand); 70% isopropyl alcohol-impregnated caps (AICs; Excelsior Medical, Neptune City, NJ); or chlorhexidine gluconate swabs with 2% CHG w/v+70% isopropanol v/v (CHG swabs; 3M, London, Ontario, Canada). For decontamination using the swabs, scrubbing consisted of back-and-forth twisting motion for 5, 15, or 30 seconds; the AICs were used for 5 minutes. After decontamination, needleless connectors were allowed to dry for 30 seconds, flushed with media, and cultured. Prior to these experiments, a negative control (no microbial contamination) and a positive control (no decontamination after microbial contamination) were studied for each needleless connector type. In addition, 3 positive and 3 negative controls were included for each connector and for contamination by each microorganism. The positive control was used to determine microbial recovery through each type of needleless connector if no decontamination occurred. These data were used to calculate the ratio of reduction in microorganisms passing through decontaminated needleless connectors, and we divided the colony count per decontamination group by the baseline colony count from the positive controls. Mean and standard deviations were calculated; t tests were used to test differences between groups, and P< .05 was considered statistically significant. Differences between needleless connector types and organisms detected were negligible; therefore, results were pooled per decontamination group. CHG swabs resulted in a greater reduction of organisms than the IPA swabs: for CHG30 (ie, a CHGwipe for 30 second) vs IPA30 (an IPA wipe for 30 seconds), t(70)= 74.32 (P< .01) Figure 1a). The AICs cleared less organisms than the CHG swabs: for CHG30 vs AIC, t(70)= 28.25 (P< .01). However, the AICs cleared more organisms than the IPA swabs: for AIC vs IPA30 swabs, t(70)= 5.01 (P< .01). On average, this result equated to 4.03 log passing through positive controls, compared to experimental pass-through logs, as follows: 0.89 for IPA5 (ratio reduction [RR], 0.78), 0.64 for IPA15 (RR, 0.84), 0.54 for IPA30 (RR, 0.87), 0.38 for IC (RR, 0.91), 0.12 for CHG5 (RR, 0.97), 0.02 for CHG15 (RR, 0.995), and 0.01 for CHG30 (RR, 0.998). In the presence of serum exposure, most comparisons of microorganism reductions remained statistically significant (Figure 1b). However, less reduction occurred in percentage colony counts without serum exposure: for CHG30 vs IPA30, t(70)= 35.14 (P< .01); for CHG30 vs AIC, t(70)= 36.09 (P< .01); and for AIC vs IPA30 swab, t(70)= 1.57 (P= 0.12). On average, 2.81 log passed through positive controls, compared to the following experimental pass-through logs: 1.19 for IPA5 (RR, 0.58); 0.75 for IPA15 (RR, 0.73); 0.55 for IPA30 (RR, 0.80); 0.49 for AIC (RR, 0.83); 0.13 for CHG5 (RR, 0.95); 0.13 for CHG15 (RR, 0.95); and 0.03 for CHG30 (RR, 0.99). A 5-second disinfection of the needleless connector with IPA swab is the standard practice at our institution. Like previous research, the results of this study suggest that it is an inadequate method for this purpose. Regarding cost, the change to CHG swabs would not be prohibitive; the 2016 purchase costs from Queensland Health were USD 0.022 (AUD 0.03) per unit for IPA swabs; USD 0.072 (AUD 0.10) per unit for CHG swabs; and USD 0.217 (AUD 0.30) per unit for infection control & hospital epidemiology

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The potential for catheter microbial contamination from a needleless connector.

Needleless connectors have been widely introduced into clinical practice to allow the connection of syringes and luers to peripheral and central vascular catheters. The potential for microbial contamination of catheters via these devices is currently unclear. A recently introduced connector, the 'Connecta Clave', was assessed by various in-vitro methods. The 'Connecta Clave' is specifically dev...

متن کامل

Disinfection of needleless catheter connectors and access ports with alcohol may not prevent microbial entry: the promise of a novel antiseptic-barrier cap.

BACKGROUND Needleless valve connectors for vascular catheters are widely used throughout the United States because they reduce the risk of biohazardous injuries from needlesticks and exposure to bloodborne pathogens, such as human immunodeficiency virus and hepatitis C virus. Patients with long-term central venous catheters are at significant risk of acquiring catheter-related bloodstream infec...

متن کامل

Scrub the hub! Catheter needleless port decontamination.

T HE central venous catheter (CVC) is an essential tool in the care of critically ill and high-risk intraoperative patients. Catheterrelated bloodstream infection (CR-BSI) related to CVC insertion technique has been greatly reduced by the use of preventive protocols. However, late CR-BSI remains a significant threat to patient safety and healthcare cost containment. Appropriate CVC maintenance ...

متن کامل

Comparing the Effects of Chlorhexidine 2% and Iodopovidone-alcohol on Peripheral Venous Catheter Bacterial Colonization in Preterm Neonates

Background: Studies regarding cleansing the area with antiseptic solutions prior to catheterization in premature infants are limited. Therefore, the present study aimed to evaluate and compare the effects of chlorhexidine 2% and iodopovidone-alcohol solutions on bacterial colonization associated with the peripheral venous catheterization in premature infants. ...

متن کامل

The Effect of Isopropyl Alcohol and Chlorhexidine Gluconate on the Blood Glucose in Diabetic Patients Referring to the Emergency Department

Introduction: Diabetes is a metabolic disorder that can cause considerable disability and mortality. The aim of controlling diabetes is to normalize blood glucose levels to reduce the progression of vascular and neurological complications. Blood glucose control and reassurance are essential for planning health care. Objective: In the present study, the effect of local isopropyl alcohol and chlo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Infection control and hospital epidemiology

دوره 38 5  شماره 

صفحات  -

تاریخ انتشار 2017