Review article: Validity of the KT-1000 knee ligament arthrometer.

نویسندگان

  • S Arneja
  • J Leith
چکیده

The KT-1000 knee arthrometer (KT-1000) is an objective instrument to measure anterior tibial motion relative to the femur for anterior cruciate ligament (ACL) reconstruction. Four studies between 1950 and 2007 regarding validity of the KT-1000 were identified using a Medline search. One had interpretable information on sensitivities, specificities, and predictive values to validate the instrument as a diagnostic tool in patients with acute or chronic ACL injuries. Three had limitations in methodology. We suggest that the KT-1000 should be used with caution as an objective instrument. Rather, using a KT-1000 score derived by subtracting the anterior tibial motion relative to the femur of the injured knee to that of the uninjured knee may be more appropriate as a dichotomous diagnostic test with a threshold of 2 or 3 mm.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intratester and intertester reliability of the KT-1000 arthrometer in the assessment of posterior laxity of the knee.

We measured tibial translation in the knees of 22 subjects with posterior cruciate ligament tears or reconstructions by using the KT-1000 arthrometer. To assess the reliability of the device, two testers made measurements. One tester was a novice and the second tester had substantial clinical experience with the KT-1000 arthrometer. The quadriceps neutral angle was found for the uninvolved knee...

متن کامل

Quantitative analysis of the measuring capabilities of the KT-1000 knee ligament arthrometer.

The KT-1000 arthrometer was evaluated in vitro and in vivo to determine accuracy and quantify effects of potential error sources in clinical application. The KT-1000 arthrometer in vitro accuracy was evaluated by making 30 measurements of 13 known displacements (range, +15 to -15 mm). The effect of applied force on malalignment measurements was evaluated in vitro by making repeated measurements...

متن کامل

Clinical outcomes of anterior cruciate ligament reconstruction using LARS artificial graft with an at least 7-year follow-up

The aim of our study was to assess the medium-term clinical outcomes of anterior cruciate ligament (ACL) reconstruction using the Ligament Advanced Reinforcement System (LARS) artificial ligament.A total of 168 patients who underwent arthroscopic ACL reconstruction with the LARS artificial ligament in our department were enrolled in our research. Only 125 met the inclusion/exclusion criteria, a...

متن کامل

Measurement of the tibial anterior-posterior translation for Lachman test in the awake state and under anesthesia using electromagnetic measurement system.

Introduction: Anterior cruciate ligament (ACL) deficiency causes an increase in anterior tibial translation. To assess the amount of the anterior-posterior tibial translation, KT-arthorometer has been widely used. However it has been suggested by some reports that the practical reliability of the KT-1000 arthrometer measurement is doubted due to the interand intra-examiner errors. The Lachman t...

متن کامل

Clinical Outcomes After Anterior Cruciate Ligament Reconstruction

BACKGROUND Clinical outcomes of autograft and allograft anterior cruciate ligament (ACL) reconstructions are mixed, with some reports of excellent to good outcomes and other reports of early graft failure or significant donor site morbidity. OBJECTIVE To determine if there is a difference in functional outcomes, failure rates, and stability between autograft and allograft ACL reconstructions....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 17 1  شماره 

صفحات  -

تاریخ انتشار 2009