Measurement of the specific heat capacity of liver phantom.
نویسندگان
چکیده
Phantoms are often used to simulate tissue during the development, testing and calibration of medical devices. In order to infer the specific absorption rate (SAR) and resistive heating in phantoms from temperature measurements, the specific heat capacity and density of the phantom are needed. Stauffer et al (2003 Int. J. Hyperth. 19 89-101) developed several phantoms that mimic dielectric properties of liver tissue at 915 MHz. However, thermal properties of the phantoms were not presented. We have measured specific heat capacities and densities for these phantoms. We also present dielectric properties for these phantoms measured from 0.7 to 20 GHz, including 2.45 GHz--a commonly used frequency for microwave hyperthermia and ablation.
منابع مشابه
Evaluation of Electron Specific Absorbed Fractions in Organs of Digimouse Voxel Phantom Using Monte Carlo Simulation Code FLUKA
Background: For preclinical evaluations of radiopharmaceuticals, most studies are carried out on mice. Values of electron specific absorbed fractions (SAF) have had vital role in the assessment of absorbed dose. In past studies, electron specific absorbed fractions were given for limited source target pairs using older reports of human organ compositions.Objective: Electron specific absorbed fr...
متن کاملPreparation of MCM-41 nanofluid and an investigation of Brownian movement of the nanoparticles on the nanofluid conductivity
In this investigation the silicate nano structure of MCM-41 has been used for the production of nanofluid. The particles have negligible heat conductivity and therefore by their dispersion in a base fluid like water, it is possible to study the increase of heat conductivity due to the Brownian motion effects. In this work a suitable apparatus for the measurement of heat conductivity has been bu...
متن کاملDetermination of Thermo-physical Properties of Non-Newtonian Fluids Using a Coaxial Cylindrical Cell
In this study the thermal conductivity and the volumetric heat capacity of non-Newtonian fluids are investigated. These fluids find many applications in chemical, medical and food industries. They mostly have viscoelastic behavior and generally differ from Newtonian fluids. Two non-Newtonian fluids, solutions of xanthan and carboxy methyl cellulose in water with various concentrations have bee...
متن کاملDevelopment of a Liver Phantom Based on Computed Tomography Images for Dosimetric Purpose
Introduction: The present study was conducted with the aim of designing a liver phantom for dosimetry. To benchmark the results obtained by the developed liver phantom, another method was applied for the dosimetry of a real liver tissue using imaging. Materials and Methods: For the purpose of the study, a real liver tissue was converted into a phantom based on thegram-molecular weight of the co...
متن کاملEstimation of Photon Specific Absorbed Fractions in Digimouse Voxel Phantom using Monte Carlo Simulation Code FLUKA
Background: Most preclinical studies are carried out on mice. For internal dose assessment of a mouse, specific absorbed fraction (SAF) values play an important role. In most studies, SAF values are estimated using older standard human organ compositions and values for limited source target pairs.Objective: SAF values for monoenergetic photons of energies 15, 50, 100, 500, 1000 and 4000 keV...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physiological measurement
دوره 27 10 شماره
صفحات -
تاریخ انتشار 2006