Leak measurements in spontaneously breathing premature newborns by using the flow-through technique.

نویسندگان

  • B Foitzik
  • M Schmidt
  • D Windstetter
  • R R Wauer
  • G Schmalisch
چکیده

A new method for measuring and correcting air leaks during lung-function testing in infants has been validated in vitro and in vivo by using a flow-through system that measured the inflow and outflow of a face mask. An adjustable leak was quantified by using suction flow to validate the accuracy of leak measurements. To validate the leak correction, the volume of a pump was measured with different air leaks (0-30%). The method developed was tested in 67 infants breathing spontaneously. There was good agreement between measured and simulated leaks (r = 0.998, P < 0.001; 95% limits of agreement were -0.3 and 0.1%, respectively). The volume was generally underestimated because of leaks, and the volume error was up to 94% compared with the maximum error of 5% after leak correction. With continuous leak measurements in vivo, there were <4% actual leaks (median 2.6%), and we did not observe any leaks in >7% of cases. The leak correction improved the accuracy of ventilatory measurements. The monitoring of leaks is helpful for airtight placement of the face mask and for prevention of serious measurement errors caused by leaks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HY POXIA AND I TS INFLUEN CES ON THE CARDIOVASCULAR AND RESPIRATORY SYSTEMS OF SPONTANEOUSLY BREATHING CATS

Effects of acute systemic hypoxia on the cardiovascular system (CYS) and respiration of spontaneously breathing cats were studied in two conditions. 1): Hypoxic air (6-8% 02 in N2) was given to the animal to induce systemic hypoxia for 20 minutes. Hyperventilation at this condition lowered arterial C02 tension (PaC02 hypocapnia). 2): In the second run, induction of hypocapnia was prevented ...

متن کامل

Effect of skin application of sun-flower oil on serum triglyceride and cholesterol in premature newborns

Introduction: Total parental nutrition is essential in premature newborns who are unable to have oral feeding. Intra venous Lipid (Intra lipid) is used to preparing essential fatty acids and a compact source of energy. We aimed in this study to investigate the effect of skin intra lipid. Methods: Premature newborns, who were through admitted in NICU unable to feed orally, were investigated in...

متن کامل

Imposed work of breathing during high-frequency oscillatory ventilation: a bench study

INTRODUCTION The ventilator and the endotracheal tube impose additional workload in mechanically ventilated patients breathing spontaneously. The total work of breathing (WOB) includes elastic and resistive work. In a bench test we assessed the imposed WOB using 3100 A/3100 B SensorMedics high-frequency oscillatory ventilators. METHODS A computer-controlled piston-driven test lung was used to...

متن کامل

Comparison of Effect of Prone and Right Lateral Positions on Gastric Residual Volume in Preterm Newborns

Background: Nutritional problems in premature newborns are of great importance for their development. In this regard, the neonatal positioning during and after feeding can have a significant effect on their nutritional tolerance. Therefore, the present study was conducted to compare the effect of two positions (i.e., prone and right lateral) on gastric residual volume ...

متن کامل

In vitro investigations of jet-pulses for the measurement of respiratory impedance in newborns.

The aim of this in vitro study was to investigate the measuring range and accuracy of a miniaturized equipment for respiratory impedance (Zrs) measurements in newborns using jet-pulses. Brief flow pulses (peak flow=16 L x min(-1), width=10 ms) were generated by a jet-generator consisting of a solenoid valve and an injector, situated between pneumotachograph and outflow resistance. Serially arra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 85 3  شماره 

صفحات  -

تاریخ انتشار 1998