Data and Analysis from a Time-resolved Tomographic Optical Beam Diagnostic*
نویسندگان
چکیده
An optical tomographic diagnostic instrument developed for the acquisition of high-speed time-resolved images has been fielded at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility at Los Alamos National Laboratory. The instrument was developed for the creation of time histories of electron-beam cross section through the collection of Cerenkov light. Four optical lines of sight optically collapse an image and relay projections via an optical fiber relay to recording instruments; a tomographic reconstruction algorithm creates the time history. Because the instrument may be operated in an adverse environment, it may be operated, adjusted, and calibrated remotely. The instrument was operated over the course of various activities during and after DARHT commissioning, and tomographic reconstructions reported verifiable beam characteristics. Results from the collected data and reconstructions and analysis of the data are discussed.
منابع مشابه
Time-Resolved C-Arm Computed Tomographic Angiography Derived From Computed Tomographic Perfusion Acquisition: New Capability for One-Stop-Shop Acute Ischemic Stroke Treatment in the Angiosuite.
BACKGROUND AND PURPOSE Multimodal imaging using cone beam C-arm computed tomography (CT) may shorten the delay from ictus to revascularization for acute ischemic stroke patients with a large vessel occlusion. Largely because of limited temporal resolution, reconstruction of time-resolved CT angiography (CTA) from these systems has not yielded satisfactory results. We evaluated the image quality...
متن کاملرفتار نورشکستی بلور تیتانات باریم و کاربردهای آن در اندازه گیریهای اپتیکی در زمان واقعی
In this research we measure some of the optical parameters of Barium Titanate crystal (BaTiO3), such as signal beam gain, coupling constant (exponential gain coefficient), change in index refraction and photorefractive sensitivity, which are very significant for optical data storage. In all experiment, two- wave mixing configuration at 632.8 nm (He- Ne laser) were used. Experimental data f...
متن کاملDiagnostics for Intense Heavy Ion Beams in the Hif-vnl*
Modern diagnostic techniques provide detailed information on beam conditions in injector, transport, and final focus experiments in the HIF-VNL. Parameters of interest include beam current, beam energy, transverse and longitudinal distributions, emittance, and space charge neutralization. Imaging techniques, based on kapton films and optical scintillators, complement and in some cases, may repl...
متن کاملUnified Pulsed Laser Range Finder and Velocimeter using Ultra-Fast Time-To-Digital Converter
In this paper, we present a high accuracy laser range finder and velocimeter using ultra-fast time-to-digital converter (TDC). The system operation is based on the measuring the round-trip time of a narrow laser pulse. A low-dark current high-speed PIN photodiode is used to detect the triggered laser beam and to produce start signal. The pulsed laser diode generates 45W optical power at 30ns du...
متن کاملTime-Resolved C-Arm Computed Tomographic Angiography Derived From Computed Tomographic Perfusion Acquisition
Patients with acute ischemic stroke (AIS), especially those because of a large vessel occlusion (LVO), have poor prognosis. Although intravenous tissue-type plasminogen activator has been shown to offer benefit in some patients with an AIS, its efficacy in those with LVOs is poor. The majority of the AIS patients with LVOs will die or have severe disability despite intravenous tissue-type plasm...
متن کامل