Seismic Behavior of Substandard RC Columns Retrofitted with Embedded Aramid Fiber Reinforced Polymer (AFRP) Reinforcement

نویسندگان

  • Engin C. Seyhan
  • Caglar Goksu
  • Alper Ilki
چکیده

Many existing reinforced concrete structures were constructed with substandard characteristics. Low quality concrete, poor transverse reinforcement details and insufficient flexural strength are among the most common deficiencies. While substandard structures are in need of retrofitting, particularly in seismic areas, problems such as high costs and disturbance to occupants are major obstacles for retrofit interventions. Fiber reinforced polymers can provide feasible retrofit solutions with minimum disturbance to occupants. In this study, the basic aim is to investigate the flexural seismic performance of substandard reinforced concrete columns retrofitted with embedded longitudinal fiber reinforced polymer reinforcement without increasing the original dimensions of the columns. In the experimental study, the reference and retrofitted columns were tested under constant vertical and reversed cyclic lateral loads. Three different connection methods of aramid fiber reinforced polymer reinforcement to the footing were investigated experimentally. A significant enhancement was obtained in lateral flexural strength through the proposed retrofitting method. Furthermore, it was observed that the cyclic lateral drift capacities of the retrofitted columns were as high as 3%, which can be deemed as quite satisfactory against seismic actions. The comparison of the experimental data with analytical calculations revealed that a conventional design approach assuming composite action between concrete and fiber reinforced polymer reinforcement can be used for flexural retrofit design. Experimental results also demonstrated that strain limit for longitudinal fiber reinforced polymer (FRP) reinforcement should be remarkably lower in case of reversed cyclic loading conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Carbon Fiber Sheet Retrofitted Rc Bridge Columns

Experimental studies were conducted by some researchers to investigate the cyclic performance of CFSretrofitted columns; however there is a need to develop analytical methods which can simulate its hysteretic response. This study presents an analysis of the hysteretic behavior of CFS-retrofitted reinforced concrete circular columns. Fiber element analysis was conducted based on cyclic constitut...

متن کامل

Effects of Using Multilayers of High Resistance AFRP on Loading Capacity of Reinforced Concrete Beams in Comparison with Low Resistance AFRP Considering EBROG Method

 Externally Bonded Reinforcement on Grooves (EBROG) is a new method that has been introduced to postpone or eliminate debonding of FRP sheets from concrete surface in concrete beams strengthened for flexure and increase loading capacity. For strengthening reinforced conceret beams in strructure, use of different types of FRP like: laminate, AFRP, CFRP, and GFRP. By there is some differences bet...

متن کامل

Retrofitting of Existing Rc Square Bridge Columns Using Basalt Frp Rebars

Fiber-reinforced polymers (FRPs) have been widely utilized to improve the seismic performance of deficient reinforced concrete (RC) columns. In recent years, one of the emerging types of FRPs used is basalt fibers. In this study, the performance of existing columns was experimentally examined before and after applying near-surface mounted (NSM) basalt FRP (BFRP) rebars as a retrofitting techniq...

متن کامل

Confinement Characteristics of Rectangular FRP-Jacketed RC Columns

In this study, FRP jackets were investigated for their confinement effectiveness on rectangular RC columns. Thirteen reduced-scale short columns were tested to failure in axial compression. Variables investigated include: the type of fibers (AFRP, CFRP or GFRP), the thickness of the jacket, the aspect ratio of the rectangular cross section and the radii of the corners. For square columns, GFRP ...

متن کامل

Microwave Cylindrical Reflection Tomography Array for Damage Detection in Civil Structures

The enhanced structural performance of Reinforced Concrete (RC) columns retrofitted by Fiber Reinforced Polymer (FRP) composite jackets, has been well demonstrated and an increasingly large number of bridge and building columns have been retrofitted with such jackets in the United States and elsewhere. However, seismic damage such as debonding between the jacket and the column that can consider...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015