Improved Contact X-Ray Microradiographic Method to Measure Mineral Density of Hard Dental Tissues

نویسندگان

  • B. D. Schmuck
  • C. M. Carey
چکیده

Contact X-ray microradiography is the current gold standard for measuring mineral densities of partially demineralized tooth specimens. The X-ray sensitive film specified in the last J Res NIST publication on the subject is no longer commercially available. OBJECTIVES: Develop a new microradiographic method by identifying a commercially available film with greater than 3000 lines per millimeter resolution, which is sensitive to X rays, and develop correct film processing for X-ray microradiographic application. METHODS: A holographic film was identified as a potential replacement film. Proper exposure was determined utilizing a thick nickel plate to create test-strips. Film development was bracketed around manufacturer suggestions. Film linearity was determined with aluminum step-wedges. Microradiographs of 100 µm thick tooth sections, before and after acidic challenges, were a final test for film. Magnified images were captured with a digital microscope camera with 0.305 micrometers per pixel resolution. RESULTS: The appropriate film exposure was 30 minutes at 80 kV(p) and 3 mA with a development time of 2 minutes. Step-wedge experiments show the system to be linear in terms of pixel intensities with respect to x-ray attenuation for normalized pixel intensity values that are 10% to 90% of full scale (r(2) = 0.997) which encompasses the full exposure region of tooth tissue. Enamel sections were analyzed and show distinctive differences between erosion and demineralization. The image capture device resolution of 0.305 micrometers per pixel limits the system resolution. CONCLUSION: Use of the identified holographic film when combined with the described processing modifications has resulted in an improved X-ray microradiographic method for the measurement of mineral density of dental hard tissues. The method described can be further improved by using a higher resolution digitization system. The method is appropriate for quantitatively measuring changes in mineral density and erosion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Singh index accuracy and dual energy X-ray absorptiometry bone mineral density measurement for evaluating osteoporosis

Background: The Singh index is an inexpensive simple method to evaluate bone density, commonly used to assess osteoporosis is based on the radiological appearance of the trabecular bone structure of the proximal femur on a plain antero-posterior (AP) radiograph. The purpose of this study was to compare between Singh index and bone mineral density measurement using dual energy X-ray abs...

متن کامل

Monte Carlo Modeling of Dual and Triple Photon Energy Absorptiometry Technique

Introduction: Osteoporosis is a bone disease in which there is a reduction in the amount of bone mineral content leading to an increase in the risk of bone fractures. The affected individuals not only have to go through lots of pain and suffering but this disease also results in high economic costs to the society due to a large number of fractures.  A timely and accurate diagnosis of this disea...

متن کامل

Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus

The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...

متن کامل

Qualitative Evaluation of Digital Hand X-rays is Not a Reliable Method to Assess Bone Mineral Density

Object: The gold standard for evaluating bone mineral density is dual energy x-ray absorptiometry (DEXA).  Prior studies have shown poor reliability using analog wrist X-rays in diagnosing osteoporosis. Our goal was to investigate if there was improved diagnostic value to visual assessment of digital hand X-rays in osteoporosis screening. We hypothesized that similar to analog counterparts, dig...

متن کامل

Introducing an Optimized Method for Obtaining X-ray Diffraction Patterns of Biological Tissues

Introduction Individual X-Ray diffraction patterns of biological tissues are obtained via interference of coherent scattering with their electrons. Many scientists have distinguished normal and cancerous breast tissue, bone density, and urinary stone types using the X-Ray diffraction patterns resulting from coherent scattering. The goal of this study was to introduce an optimized method for obt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 115  شماره 

صفحات  -

تاریخ انتشار 2010