Is a Metallic Microcoil Really a Permanent Embolic Agent for the Management of Distal Guidewire-Induced Coronary Artery Perforation?

نویسندگان

  • Jae Hyun Kim
  • Min-Kyu Kim
  • Young Jin Kim
  • Sun Man Park
  • Kyoung-Ha Park
  • Young-Jin Choi
چکیده

Coronary artery perforation (CAP) after percutaneous coronary intervention is a rare, but serious complication. It can cause cardiac tamponade, acute myocardial infarction or death. The treatments of CAP involve prolonged balloon inflation, emergent surgery, coil embolization, and implantation of covered stent. We have successfully performed the emergent microcoil embolization in a patient with uncontrolled Ellis grade 3 guidewire-induced CAP resulting in delayed cardiac tamponade. Contrasting our usual expectation, the 1-year follow-up angiography showed a patent flow at the embolized site.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Cardiac perforation complicated by cardiac tamponade and sealed with metallic coils].

Distal coronary artery perforation with an angioplasty guidewire is a rare complication that may cause cardiac tamponade, myocardial infarction, arrhythmia, and even death. The use of platelet IIb/IIIa glycoprotein receptor inhibitors increases the risk of potentially fatal complications that are difficult to manage. We report a patient on treatment with abciximab who presented coronary perfora...

متن کامل

The successful use of autologous skin in management of guidewire‐induced distal coronary perforation

The successful use of autologous skin to management may provide a useful and widely applicable method for dealing with the troublesome complication of guidewire-induced coronary perforation.

متن کامل

Simple and inexpensive way for the treatment of guidewire-induced distal coronary perforation: subcutaneous fat tissue embolization

cardial infarction was admitted to the catheterization laboratory for primary percutaneous coronary intervention. Left anterior descending artery (LADa) was seen subtotally occluded immediately after the first diagonal artery (D1a) branching with TIMI 1 distal flow on coronary angiogram (Fig. 1a–c, Video 1–3). LADa and D1a were passed by a soft guidewire. After predilatation of the culprit lesi...

متن کامل

Collagen embolization for the successful treatment of a distal coronary artery perforation.

A 42-year old man suffered a coronary artery perforation in the right coronary artery secondary to a hydrophilic guidewire. We describe for the first time the use of collagen embolization to successfully treat this complication.

متن کامل

Surgical management for retained distal embolic protection device and fractured guidewire after carotid artery stenting

Entrapment and fracture of carotid angioplasty and stenting hardware is a rare complication of percutaneous stenting procedures. We describe a case of a retained distal filter embolic protection device and guidewire in a 57-year-old male in Beijing, China. After unsuccessful attempts at removal via interventional methods, a second stent was deployed to secure the original hardware in situ, and ...