Assessment of Minimum 124I Activity Required in Uptake Measurements Before Radioiodine Therapy for Benign Thyroid Diseases.
نویسندگان
چکیده
UNLABELLED This study aimed to assess a hypothetical minimum administered activity of (124)I required to achieve comparability between pretherapeutic radioiodine uptake (RAIU) measurements by (124)I PET/CT and by (131)I RAIU probe, the clinical standard. In addition, the impact of different reconstruction algorithms on (124)I RAIU and the evaluation of pixel noise as a parameter for image quality were investigated. METHODS Different scan durations were simulated by different reconstruction intervals of 600-s list-mode PET datasets (including 15 intervals up to 600 s and 5 different reconstruction algorithms: filtered-backprojection and 4 iterative techniques) acquired 30 h after administration of 1 MBq of (124)I. The Bland-Altman method was used to compare mean (124)I RAIU levels versus mean 3-MBq (131)I RAIU levels (clinical standard). The data of 37 patients with benign thyroid diseases were assessed. The impact of different reconstruction lengths on pixel noise was investigated for all 5 of the (124)I PET reconstruction algorithms. A hypothetical minimum activity was sought by means of a proportion equation, considering that the length of a reconstruction interval equates to a hypothetical activity. RESULTS Mean (124)I RAIU and (131)I RAIU already showed high levels of agreement for reconstruction intervals of as short as 10 s, corresponding to a hypothetical minimum activity of 0.017 MBq of (124)I. The iterative algorithms proved generally superior to the filtered-backprojection algorithm. (124)I RAIU showed a trend toward higher levels than (131)I RAIU if the influence of retrosternal tissue was not considered, which was proven to be the cause of a slight overestimation by (124)I RAIU measurement. A hypothetical minimum activity of 0.5 MBq of (124)I obtained with iterative reconstruction appeared sufficient both visually and with regard to pixel noise. CONCLUSION This study confirms the potential of (124)I RAIU measurement as an alternative method for (131)I RAIU measurement in benign thyroid disease and suggests that reducing the administered activity is an option. CT information is particularly important in cases of retrosternal expansion. The results are relevant because (124)I PET/CT allows additional diagnostic means, that is, the possibility of performing fusion imaging with ultrasound. (124)I PET/CT might be an alternative, especially when hybrid (123)I SPECT/CT is not available.
منابع مشابه
The optimal time of discountinuing Methimazole before radioiodine therapy [Persian]
Hyperthyroidism is a common disease and one of the best methods for its treatment is radioiodine therapy. Treatment with antithyroid drugs brings patients to euthyroidism before radioiodine therapy. Antithyroid drugs should be discontinued before radioiodine therapy to increase thyroid uptake. The purpose of this study was to determine the optimal time of methimazole (MTZ) discontinuation...
متن کاملAssessment of minimum activity of 124Iodine in pre-therapeutic uptake measurement prior to radioiodine therapy of benign thyroid diseases
متن کامل
Multiple non-malignant iodine uptake in a 131I whole body scan of a patient with papillary thyroid carcinoma: Importance of SPECT/CT
After thyroidectomy in papillary thyroid carcinoma (PTC) patients, whole body radioiodine scan (WBIS) is necessary for localization of any abnormal radioiodine avid lesions. However false-positive radioiodine uptake in WBIS can be problematic. We report a 32 years old female patient with PTC. After thyroidectomy and radioiodine therapy WBIS was performed. In her post therapy WBIS, there were zo...
متن کاملChanges in salivary gland function following radioiodine therapy of thyroid diseases: A comparison of high-dose therapy for thyroid cancer and low-dose therapy for benign thyroid disease
Introduction: High-dose radioactive iodine therapy in differentiated thyroid cancer (DTC) may adversely affect the salivary gland function. This study is aimed to evaluate the effect of radioactive iodine (RAI) with dose of 100 mCi in DTC patients compared to lower doses of less than 30 mCi in hyperthyroid cases. Methods: Fifty four patients (13 men and 41 women) age: 42.3±14.3 (21-71) years w...
متن کاملRadioiodine avid adenomatous colon polyp in a post-treatment whole body radioiodine scan
A 47 year old female with papillary thyroid carcinoma was referred to our department for post-treatment whole body iodine scanning. The acquired images revealed a focal zone of intense radiotracer uptake in the right lower quadrant of the abdomen. SPECT/CT fused slices showed a focal zone of the radioiodine (131I) uptake in the right colon wall. Colonoscopy revealed a pedunculated po...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 57 8 شماره
صفحات -
تاریخ انتشار 2016