Biomechanical Evaluation of Interfragmentary Compression At Tibia Plateau Fractures In Vitro Using Different Fixation Techniques
نویسندگان
چکیده
Reliable osteosynthesis of intraarticular fractures depends on lasting interfragmentary compression. Its amount differs in the applied fixation method. The interfragmentary compression of cancellous and cortical lag screws and angle stable locking plates was quantified in an osteoporotic and non-osteoporotic synthetic human bone model.A split fracture of the lateral tibia plateau (AO/OTA type 41-B1.1) was mimicked by an osteotomy in right adult synthetic human tibiae with hard or soft cancellous bone. Specimens were fixed with either two 6.5 mm cancellous, four 3.5 mm cortical lag screws, or 3.5 mm LCP proximal lateral tibia plate preliminary compresed by a reduction clamp (n = 5 per group). A pressure sensor film was used to register the interfragmentary compression. One-way analysis of variance (ANOVA) with Bonferroni post hoc correction was performed for statistical analysis (p < 0.05).Interfragmentary compression under reduction clamp was 0.59 ± 0.12 MPa in the non-osteoporotic and 0.55 ± 0.14 MPa in the osteoporotic group. The locking plate itself maintained the compression in non-osteoporotic (0.53 ± 0.11 MPa) and osteoporotic bone (0.50 ± 0.14 MPa). Four 3.5 mm cortical lag screws provided a compression of 1.69 ± 0.65 MPa in non-osteoporotic bone, being not significantly different to the osteoporotic bone group (1.43 ± 0.47 MPa, P = 1.0). Two 6.5 mm cancellous lag screws showed a significantly higher compression in non-osteoporotic (2.1 ± 0.59 MPa) compared to osteoporotic (0.77 ± 0.21 MPa, P < 0.01) bone.Angle stable locking plates maintained the compression preliminarily applied by a reduction clamp. Two 6.5 mm cancellous lag screws are especially suited for non-osteoporotic bone, whereas four 3.5 mm cortical screws exhibited comparable compression in both bone qualities.
منابع مشابه
Biomechanical Evaluation of Interfragmentary Compression At Tibia Plateau Fractures In Vitro Using Different Fixation Techniques: A CONSORT-Compliant Article: Erratum.
[In the article "Biomechanical Evaluation of Interfragmentary Compression At Tibia Plateau Fractures In Vitro Using Different Fixation Techniques: A CONSORT-compliant" article, which appeared in Volume 94, Issue 1 of Medicine, a line denoting dual authorship was omitted. K. Kojima and B. Gueorguiev contributed equally to the article.].
متن کاملUnion Following Biological and Rigid Fixations of Distal Tibia Extra-articular Fractures
Background: Distal tibia fractures are among the most common bony injuries, with a significant rate of nonunion anddelayed union. There are multiple methods for the management of distal tibia fractures. Among the plating methods,there are bridge plating and compression plating techniques. There is still a lack of evidence about whether one methodhas a higher rate of union than...
متن کاملThe use of combined 3.5 LCP unicortical plate and nail fixation in proximal tibia fractures and prevention of valgus and anterior angulation
Introduction: Intramedullary nailing (IMN) of high tibia fracture has some mechanical and biological advantages over the other form of fixation. However, valgus, apex anterior malalignment and anterior displacement of proximal fragment commonly occur after isolated IMN fixation of proximal high tibia fracture. The purpose of this study is to determine the effectiveness of using 3.5-mm locking c...
متن کاملBiomechanical comparison of straight DCP and helical plates for fixation of transverse and oblique bone fractures.
PURPOSE Biomechanical comparison of straight DCP and helical plates for fixation of transversal and oblique tibial bone fractures were analyzed and compared to each other by axial compression, bending and torsion tests. METHOD An in vitro osteosynthesis of transverse (TF) and oblique bone fracture (OF) fixations have been analysed on fresh sheep tibias by using the DCP and helical compression...
متن کاملA biomechanical study comparing the compressive forces generated by a conventional 4.5 AO/ASIF cortical lag screw with a differentially pitched cortical compression screw.
The aim of this study was to compare the interfragmentary compression generated across a simulated femoral fracture model by a conventional 4.5 mm AO/ASIF cortical lag screw with a differentially pitched cortical compression screw. A 45-degree osteotomy was made in a whole bone composite femoral shaft, this was internally fixed with either a conventional 4.5 mm AO/ASIF cortical lag screw or the...
متن کامل