Early markers of nephrotoxicity in patients with metal-on-metal hip arthroplasty.
نویسندگان
چکیده
BACKGROUND Metal ions released from arthroplasty devices are largely cleared in urine, leading to high exposure in renal tissues. Validated early markers of renal damage are routinely used to monitor workers in heavy metal industries, and renal risk can be quantified in these industries. It is unclear if the ion levels in patients with metal-on-metal hips are sufficient to cause renal damage. QUESTION Does metal-on-metal (MOM) bearing use over a 10-year period lead to elevation of early renal markers compared with the levels expected in subjects with no metal exposure? METHODS We retrospectively reviewed 31 patients who underwent MOM hip resurfacings 10 years earlier. Whole blood specimens were collected for metal ion analysis, serum for creatinine estimation, and urine for timed metal ion output and renal markers. The renal marker levels of 30 age- and gender-matched subjects with no metal exposure and no known renal problems or diabetes mellitus were used as controls for renal markers. RESULTS Median serum creatinine level in the MOM group was 1.1 mg/dL (interquartile range, 1.0-1.2 mg/dL) and median creatinine clearance was 79.2 mL/min. In this cohort, the number of patients with markers of renal damage above the reference range was comparable to the controls. None of the renal markers were associated with metal levels. CONCLUSION The absence of elevation of renal markers in this cohort 10 years after MOM bearing implantation is reassuring. However, we believe surveillance through further longer-term, large-scale controlled trials are needed to monitor this arthroplasty-induced low-intensity (but long-term) trace element exposure to rule out potential nephrotoxicity.
منابع مشابه
Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature
Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...
متن کاملMetal ion levels in the blood of patients after hip resurfacing: a comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses.
BACKGROUND Metal ion toxicity, metal hypersensitivity, and metal carcinogenicity are causes for concern for patients with metal-on-metal hip replacements. Thus, understanding the biological fate of metal ions, and consequently their long-term systemic effects, is of great interest to patients and surgeons alike. METHODS Inductively coupled plasma mass spectrometry was used to measure the leve...
متن کاملSilent soft tissue pathology is common with a modern metal-on-metal hip arthroplasty
BACKGROUND AND PURPOSE Adverse reactions to metal debris have been reported to be a cause of pain in metal-on-metal hip arthroplasty. We assessed the incidence of both symptomatic and asymptomatic adverse reactions in a consecutive series of patients with a modern large-head metal-on-metal hip arthroplasty. METHODS We studied the early clinical results and results of routine metal artifact-re...
متن کاملMetal-on-metal total hip arthroplasty: causes and high incidence of early failure.
Early failures of metal-on-metal total hip arthroplasty (THA) occur due to aseptic loosening, metal hypersensitivity reactions, pseudotumor formation, and component seizing. The purpose of this study was to investigate the timing, common modes of failure, clinical outcomes, and incidence of metal-on-metal THA revisions. A review was performed of 80 patients who underwent revision of a failed me...
متن کاملMetal-on-Metal Hip Arthroplasty: A Review of Adverse Reactions and Patient Management
Recent alarming joint registry data highlighting increased revision rates has prompted further research into the area of metal-on-metal hip replacements and resurfacings. This review article examines the latest literature on the topic of adverse reactions to metal debris and summarises the most up-to-date guidelines on patient management. Adverse reactions to metal debris can cause significant ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical orthopaedics and related research
دوره 469 6 شماره
صفحات -
تاریخ انتشار 2011