Legionella colonization of powder paint pretreatment tunnels.

نویسندگان

  • Paul Williams
  • Wai-Kin Liu
  • Nic Coetzee
  • Lynne Boulton
چکیده

We write to highlight a previously potentially overlooked source of Legionnaires’ disease. Two middle-aged men from the same factory were diagnosed with Legionnaires’ disease in the same week. A joint investigation by Health and Safety Executive (HSE), Health Protection Agency, Local Authority Environmental Health Officers, and the company concerned identified an aqueous pretreatment tunnel as the potential cause (Coetzee et al., 2009). Aqueous pretreatment tunnels are designed to spray steel parts with degreaser and phosphate to clean and prepare the parts for paint spraying. After each stage, water is used to spray the parts to rinse off excess degreaser and phosphate. This generates vapour that may be inhaled after escaping from either end of the tunnel or via overhead monorail slots. Although the water is not heated, the degreaser and phosphate tanks are raised to 55–60 C. Through contact and run off this raises water temperatures to 30–40 C typically. The water is recycled and stored, which together with nutrients from iron and debris may encourage Legionella colonization. Sampling confirmed the presence of Legionella pneumophila (LP) in the water tanks (1.7 to 3 10 c.f.u. ml ). Other similar tunnels were tested with four of five proving positive for LP growth (range 41–1800 c.f.u. ml ). Pretreatment tunnels differ from cooling towers in several respects. They may have extraction, but unlike cooling towers drift eliminators are not routinely fitted. Vapours escape at sufficiently high level to allow distribution throughout a factory. Furthermore, since the water tanks may hold tens of thousands of litres, water is conserved and recycled. The business need to run the plant to capacity and a design that renders cleaning difficult to achieve effectively may lead to the accumulation of debris and biofilm. Risk assessments undertaken by apparently specialist companies in other plants had concluded that the risk was ‘low’ and no specific action was recommended. No previous case reports have been found, supporting the assertion that the risk may be ‘low’. However, the presence of water being stored .20 C, nutrients, and generation of spray implies a foreseeable risk and we contend that action is required (HSE, 2000). Control actions might include:

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارتباط آلودگی آب به لژیونلا با عناصر جزئی در سامانه آب بیمارستان‌های منتخب تهران

Background and purpose: Water microelements can influence the growth and colonization of Legionella and infections associated with these bacteria. This research investigated Legionella contamination of water regarding microelements, alkalinity and hardness in selected hospitals of Tehran. Materials and methods: Hundred-fifty samples with 4 L volume were collected from cold and warm water sys...

متن کامل

Enhancing Skid Resistance of Two-Component Road Marking Paint using Mineral and Recycled Materials

Low skid resistance of road marking paint is one of the major issues in the safety of vehicle drivers, cyclists, and pedestrians when traveling on the city streets. Among the variety of marking paint, two-component paint is widely used at intersections and roundabouts. Therefore, the paint used should have adequate skid resistance. The object of this study was to evaluat...

متن کامل

Reducing Legionella Colonization of Water Systems with Monochloramine

Monochloramine disinfection of municipal water supplies is associated with decreased risk for Legionnaires' disease. We conducted a 2-year, prospective, environmental study to evaluate whether converting from chlorine to monochloramine for water disinfection would decrease Legionella colonization of hot water systems. Water and biofilm samples from 53 buildings were collected for Legionella cul...

متن کامل

Legionella species colonization of water distribution systems, pools and air conditioning systems in cruise ships and ferries

BACKGROUND Legionnaires' disease continues to be a public health concern in passenger ships. This study was scheduled in order to investigate Legionella spp. colonization of water distribution systems (WDS), recreational pools, and air-conditioning systems on board ferries and cruise ships in an attempt to identify risk factors for Legionella spp. colonization associated with ship water systems...

متن کامل

CONTROLLING LEGIO!NELIA IN HOSPITAL WATERSYSTEMS: EXPERIENCE WITH THE SUPERHEAT-AND-FLUSH METHOD AND COPPER-SaVER IONIZATION

ORJECI1VE: To evaluate the effect of copper-silver ionization on Legionella colonization and nosocomial legionnaires' disease and to compare the efficacy of metal ions versus the superheat-and-tlush method of disinfection. DESIGN: Prospective determination over a 36-month period of copper and silver ion concentrations in the recirculating hotwater system, Legionella colonization of the hospital...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of occupational hygiene

دوره 54 4  شماره 

صفحات  -

تاریخ انتشار 2010