AIM Drug-eluting stents have considerably reduced restenosis. Their relative merits have been assessed on the basis of comparisons made with control bare stents with thick struts. However, increased strut thickness negatively affects restenosis. No direct comparisons between drug-eluting stents and bare stents with thin struts have been performed. The aim of this study was to evaluate the relative efficacy of sirolimus-eluting stents (Cypher) as compared with that of bare stents with thin struts (BeStent 2). METHODS AND RESULTS A total of 500 patients with coronary artery disease were randomly assigned to receive a Cypher stent or BeStent. The primary endpoint was angiographic restenosis defined as a stenosis diameter > or = 50% at 6-month angiographic follow-up. The secondary endpoint was the need for target vessel revascularization (TVR) during the year following the procedure. Follow-up angiography was performed in 81.8% of the patients. Patients treated with Cypher stents had a lower angiographic restenosis rate [8.3 vs. 25.5%, relative risk, 0.33 (95% confidence interval, 0.19-0.56), P<0.001] and a lower incidence of TVR [7.2 vs. 18.8%, relative risk, 0.38 (0.22-0.66), P<0.001]. For smaller vessels (< 2.8 mm), the angiographic restenosis rates were 7.0% with the Cypher stent and 34.2% with the BeStent (P<0.001). For larger vessels (> or = 2.8 mm), angiographic restenosis rates were 10.0% with the Cypher stent and 13.1% with the BeStent (P=0.52). CONCLUSION The drug-eluting stent, Cypher, is associated with a significantly lower risk of restenosis compared with the bare thin-strut BeStent. The advantage of the Cypher stent is vastly reduced in large vessels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Comparative analysis of intimal hyperplasia after sirolimus-eluting stent and thin-strut bare-metal stent implantation in small coronary arteries].

OBJECTIVE This study aimed at evaluating reduction in intimal hyperplasia volume following angioplasty using sirolimus-eluting stents (Cypher) compared with thin-strut bare-metal stents (Pixel) in patients with small vessels. METHODS Eighty patients with coronary artery disease were prospectively included in two consecutive series, the first using sirolimus-eluting stents (50) and the second ...

متن کامل

A stent is not just a stent: Stent construction and design do matter in its clinical performance.

The undisputed superiority of stents over conventional balloon angioplasty has resulted in a plethora of stents in clinical use. Recent data, however, have indicated not all stent models are the same. Nuances in stent design and construction have impacted significantly on the immediate and long-term clinical outcome. Among the stainless steel stents, those with multicellular or tubular designs ...

متن کامل

Primary Stenting of Totally Occluded Native Coronary Arteries II (PRISON II): a randomized comparison of bare metal stent implantation with sirolimus-eluting stent implantation for the treatment of total coronary occlusions.

BACKGROUND Sirolimus-eluting stents markedly reduce the risk of restenosis compared with bare metal stents. However, it is not known whether there are differences in effectiveness between bare metal and sirolimus-eluting stents in patients with total coronary occlusions. METHODS AND RESULTS In a prospective, randomized, single-blind, 2-center trial, we enrolled 200 patients with total coronar...

متن کامل

Drug-eluting stents for diabetes mellitus

The two pivotal U.S. trials of drug-eluting stents do not establish the principle that these stents are superior to thin-strut bare-metal stents for preventing repeat revascularization in patients with diabetes. Neither study was adequately powered to make this determination. Moreover, both studies used thick-strut stents known to have high restenosis rates as controls. Low angiographic follow-...

متن کامل

Second Generation Drug-Eluting Stents: A Review of the Everolimus-Eluting Platform

Everolimus-eluting stents (EES) represent the next generation of drug-eluting stents (DES). Important design modifications include thin strut stent backbones, less inflammatory and more biocompatible polymers, and lower drug dosing. The cobalt chromium EES fluoropolymer XIENCE V stent has been the most extensively studied of such stents. In animal models, this stent demonstrated minimal vessel ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 26 13  شماره 

صفحات  -

تاریخ انتشار 2005