System suitability in bioanalytical LC/MS/MS.

نویسندگان

  • Chad J Briscoe
  • Mark R Stiles
  • David S Hage
چکیده

System suitability is widely recognized as a critical component of bioanalysis. This paper discusses a generic system suitability test that monitors instrument performance throughout a run when used for liquid chromatography tandem mass spectrometry (LC/MS/MS) in bioanalysis. This system suitability process is designed to ensure that the LC/MS/MS system is performing in a manner that leads to the production of accurate and reproducible data that can be submitted with confidence to regulatory agencies. This process contains tests for signal stability, carryover, and instrument response. This approach is integrated throughout an analytical run and has been used in the analysis of over 25,000 batches of clinical samples. Two case studies are presented in which quality control samples and standards meet all acceptance criteria (based on Standard Operating Procedures and the Food and Drug Administration's recommendations for bioanalytical method validation) but failed the proposed system suitability test, and thus were rejected. In these case studies, the concentrations of a significant number of clinical samples (over 35%) were affected, resulting in changes of more than 15% when the samples were reanalyzed. These data indicate that the poor performance of an LC/MS/MS system could adversely affect the calculated concentrations of unknown samples even though the results for quality control samples appear to be acceptable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry

The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...

متن کامل

Approaches to Analyzing Therapeutic Peptides and Proteins by LC-MS/MS

Our interest in analyzing peptides and proteins arises from the need, during preclinical and clinical studies, to quantify levels of protein and peptide drugs and their metabolites (the process of bioanalysis). To support the predicted increase in peptides and proteins undergoing such studies, we expect that the demand for immunological and LC-MS/MS bioanalytical methods to increase. We have be...

متن کامل

Systematic Troubleshooting for LC/MS/MS

www.pharmtech.com evelopment and validation of bioanalytical methods for pharmaceutical product analysis are common rate-limiting steps in biopharmaceutical product development. A rational, strategic approach to developing robust, automated, validated bioanalytical methods can reduce slowdowns and bottlenecks in drug development and contribute to synergistic, consistent, longterm performance. T...

متن کامل

Current role of LC-MS in therapeutic drug monitoring.

The role of liquid chromatography coupled with mass spectrometry (LC-MS) techniques in routine therapeutic drug monitoring activity is becoming increasingly important. This paper reviews LC-MS methods published in the last few years for certain classes of drugs subject to therapeutic drug monitoring: immunosuppressants, antifungal drugs, antiretroviral drugs, antidepressants and antipsychotics....

متن کامل

Chip-based nLC-TOF-MS is a highly stable technology for large-scale high-throughput analyses.

Many studies focused on the discovery of novel biomarkers for the diagnosis and treatment of disease states are facilitated by mass spectrometry-based technology. HPLC coupled to mass spectrometry is widely used; miniaturization of this technique using nano-liquid chromatography (LC)-mass spectrometry (MS) usually results in better sensitivity, but is associated with limited repeatability. The ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of pharmaceutical and biomedical analysis

دوره 44 2  شماره 

صفحات  -

تاریخ انتشار 2007