Feasibility of a multimodal F-FDG-directed lymph node surgical excisional biopsy approach for appropriate diagnostic tissue sampling in patients with suspected lymphoma
نویسندگان
چکیده
Background: F-FDG PET/CT imaging is widely utilized in the clinical evaluation of patients with suspected or documented lymphoma. The aim was to describe our cumulative experience with a multimodal F-FDG-directed lymph node surgical excisional biopsy approach in patients with suspected lymphoma. Methods: Thirteen patients (mean age 51 (±16;22–76) years), with suspected new or suspected recurrent lymphoma suggested by F-FDG-avid lesions seen on prior diagnostic whole-body PET/CT imaging, were injected IV with F-FDG prior to undergoing same-day diagnostic lymph node surgical excisional biopsy in the operating room. Various F-FDG detection strategies were used on the day of surgery, including, (1) same-day pre-resection patient PET/CT; (2) intraoperative gamma probe assessment; (3) clinical scanner specimen PET/CT imaging of whole surgically excised tissue specimens; (4) specimen gamma well counts; and/or (5) same-day post-resection patient PET/CT. Results: Same-day F-FDG injection dose was 14.8 (±2.4;12.5-20.6) millicuries or 548 (±89;463–762) megabecquerels. Sites of F-FDG-avid lesions were 4 inguinal, 3 cervical, 3 abdominal/retroperitoneal, 2 axillary, and 1 gluteal region subcutaneous tissue. Same-day pre-resection patient PET/CT was performed on 6 patients. Intraoperative gamma probe assessment was performed on 13 patients. Clinical scanner PET/CT imaging of whole surgically excised tissue specimens was performed in 10 cases. Specimen gamma well counts were performed in 6 cases. Same-day post-resection patient PET/CT imaging was performed on 8 patients. Time from F-FDG injection to same-day pre-resection patient PET/CT, intraoperative gamma probe assessment, and same-day post-resection patient PET/CT were 76 (±8;64–84), 240 (±63;168–304), and 487 (±104;331–599) minutes, respectively. Time from F-FDG injection to clinical scanner PET/CT of whole surgically excised tissue specimens was 363 (±60;272–446) minutes. Time from F-FDG injection to specimen gamma well counts was 591 (±96;420–689) minutes. Intraoperative gamma probe assessment successfully identified F-FDG-avid lesions in 12/13 patients. Histopathologic evaluation confirmed lymphoma in 12/13 patients and benign disease in 1/13 patients. Conclusions: A multimodal approach to F-FDG-directed lymph node surgical excisional biopsy for suspected lymphoma is technically feasible for guiding appropriate diagnostic tissue sampling of lymph nodes seen as F-FDG-avid lesions on diagnostic F-FDG PET/CT imaging.
منابع مشابه
Peripheral Lymphadenopathy: Approach and Diagnostic Tools
Peripheral lymph nodes, located deep in the subcutaneous tissue, clean antigens from the extracellular fluid. Generally, a normal sized lymph node is less than one cm in diameter. Peripheral lymphadenopathy (LAP) is frequently due to a local or systemic, benign, self-limited, infectious disease. However, it could be a manifestation of underlying malignancy. Seventy-five percent of all LAPs are ...
متن کاملDiagnostic performance of 18F-FDG PET-CT in patients presenting with secondary neck nodes from an unknown primary
Introduction: Clinical examination and even anatomical imaging may fail to identify primary site of malignancy in patients presenting with cervical nodal metastasis. 18F-Fluorodeoxyglucose Positron Emission Computed Tomography (18F-FDG PET-CT) is known to overcome the limitations of anatomic imaging. Methods: Sixty-three (63) patient...
متن کاملRare ocular and skin lesions of Marginal Zone Lymphoma detected by 18F-FDG PET/CT
We report a case of a 75-year old man that came at hematologist’s attention for lymphoma evaluation due to axillary lymph node enlargement and fever. Thorax, abdomen and pelvis Contrast-Enhanced Computed Tomography (CECT) showed lymph nodes, spleen and liver lesions. Axillary lymph node biopsy was performed and the diagnosis of marginal zone lymphoma (MZL) at stage IV was postulated, then the p...
متن کاملThe Diagnostic Accuracy of Fine Needle Aspiration Cytology in Neck Lymphoid Masses
Background and Objective: Fine needle aspiration cytology (FNAC) is a well-established method of diagnosis in palpable masses of various sites. This study was conducted to evaluate the usefulness of FNAC as a diagnostic tool in the management of patients with cervical lymphadenopathy. Patients and Methods: Totally 178 patients admitted to Loghman-Hakim Hospital , Tehran, Iran, with cervical ma...
متن کاملSentinel lymph node biopsy correctly predicts regional lymph node recurrence in trunk malignant melanoma with multiple drainage basins
We report a young male with an initial excisional biopsy report of melanoma of the lower back, referred to our hospital for complete excision and sentinel lymph node (SLN) biopsy. Four peritumoral intradermal Tc-99m phytate injection was performed and SLNs were detected in both axillary and right inguinal regions. On the biopsy only the right axillary SLN was metastatic leading to right axilla...
متن کامل