Measurements with fluoride ion selective electrode
ثبت نشده
چکیده
Where E0 is the standard electrode potential, R is the universal gas constant, T is the absolute temperature, z is the number of moles of electrons transferred in the cell reaction or halfreaction, F is the Faraday-constant, and cox and cred are the concentrations of the oxidized and reduced forms of the component. The potential of the hydrogen electrode is declared to be 0.000 V at all temperatures. Potentials of any other electrodes are determined by being compared with that of the standard hydrogen electrode at the same temperature.
منابع مشابه
Determination of Fluoride in the Bottled Drinking Waters in Iran
Fluoride is recognized as an effective agent for dental caries prevention. Generally, the main source of fluoride intake is drinking water. In this study, fluoride content in 18 commercial brands of bottled waters was investigated. Six samples from each batch of 18 Iranian commercial brands of bottled waters were supplied. The fluoride content of samples was analyzed by Fluoride Ion Selective E...
متن کاملDetermination of Fluoride in the Bottled Drinking Waters in Iran
Fluoride is recognized as an effective agent for dental caries prevention. Generally, the main source of fluoride intake is drinking water. In this study, fluoride content in 18 commercial brands of bottled waters was investigated. Six samples from each batch of 18 Iranian commercial brands of bottled waters were supplied. The fluoride content of samples was analyzed by Fluoride Ion Selective E...
متن کاملFabrication of an Electrochemical Sensor Based on a New Nano-ion Imprinted Polymer for Highly Selective and Sensitive Determination of Molybdate
In this work a new chemically modified carbon paste electrode was constructed for accurate, simple, sensitive and selective determination of molybdenum (VI) ions. The results of modified electrode by an ion imprinted polymer were compared with those obtained with carbon paste electrode. The results showed the stripping peak currents had a dramatic increase at the modified electrode. Under the o...
متن کاملSelective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.
A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...
متن کاملValidation of an ion selective electrode system for the analysis of serum fluoride ion
A high impedance unit was developed for use with a fluoride/pH electrode system for the measurement of serum fluoride. The linearity, accuracy, precision and detection limit of the system is reported. At a pH of 1.55, the system was linear over a range of serum fluoride concentrations up to 100 mumol l(-1), with a lower limit of detection of 0.3 mumol l(-1). Recoveries at this pH were 94-105% i...
متن کامل