Experience with the Artisan phakic intraocular lens in Asian eyes.

نویسندگان

  • Naoko Asano-Kato
  • Ikuko Toda
  • Yoshiko Hori-Komai
  • Chikako Sakai
  • Teruki Fukumoto
  • Hiroyuki Arai
  • Murat Dogru
  • Yoji Takano
  • Kazuo Tsubota
چکیده

PURPOSE To investigate the efficacy and safety of implantation of an iris-claw phakic intraocular lens (PIOL), Artisan Myopia, in Asian eyes. SETTING Minamiaoyama Eye Clinic, Tokyo, Japan. METHODS Forty-four eyes of 32 Japanese patients and 1 Korean patient with high myopia had Artisan Myopia lens implantation to correct their refractive errors. Lens models, 5/8.5 or 6/8.5 (optic diameter/overall diameter), were chosen as standard lens model. A smaller lens model (5/7.5-Artisan Myopia Small) was implanted in eyes with corneal diameter less than 11.0 mm. Postoperative examinations were performed on 1 day, 1 week, 1 month, 3 months, 6 months, 1 year, and 2 years after surgery. Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), manifest refraction, corneal endothelial cell counts, intraocular pressure, and complications were evaluated. RESULTS Artisan Myopia Small lenses were implanted in 4 eyes (9.1%) and 8.5 mm diameter lenses were implanted in 40 eyes. Preoperative UCVA (logMAR) improved from 1.57 to 0.09 at 1 month after surgery and no regression was observed thereafter. Postoperative manifest refraction was -1.02 +/- 0.87 D (-3.25 to -0.00 D), and within 1.0 D in 20 eyes (55.6%), within 2.0 D in 32 eyes (88.9%) at 1 month after surgery, and stable during the follow-up period. The final BCVA decreased 2 lines in 2 eyes (4.5%) due to progression of age-related cataract. No serious complications such as angle closure or progressive endothelial cell loss were observed. CONCLUSION Implantation of an Artisan iris-claw PIOL implantation may be a safe and effective procedure for Asian eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artisan toric phakic intraocular lens for the correction of high astigmatism.

PURPOSE To evaluate efficacy, predictability, and safety of Artisan toric phakic intraocular lens (Ophtec, Groningen, The Netherlands) implantation for the correction of astigmatism higher than 2 diopters. DESIGN Interventional case series. METHODS This prospective study included 27 eyes of 16 patients with a mean preoperative spherical equivalent of -11.78 +/- 6.24 diopters and a mean preo...

متن کامل

A retrospective analysis of the first Indian experience on Artisan phakic intraocular lens.

PURPOSE To evaluate the efficacy, safety, predictability and stability of implanting a polymethylmethacrylate phakic intraocular lens (PIOL) in high myopia. MATERIALS AND METHODS A retrospective analysis of the data of patients who underwent Artisan phakic IOL implantation between 2002 and 2003 with a follow-up of at least 24 months. RESULTS An Artisan myopia lens was implanted in 60 eyes o...

متن کامل

Refractive lens exchange versus iris-claw Artisan phakic intraocular lens for hyperopia.

PURPOSE To study a paired-match comparison between refractive lens exchange with pseudophakic IOL implant (RLE) and Artisan phakic IOL for high hyperopia. METHODS Nineteen eyes (12 patients, 20 to 41 years old) with an Artisan phakic IOL (Model 203: 1.00-D increment) for hyperopia from +2.75 to +9.25 D were matched to 19 eyes (15 patients, 26 to 46 yr) with hyperopia from +2.75 to +7.50 D, wh...

متن کامل

Phakic intraocular lenses to correct high myopia: Adatomed, Staar, and Artisan.

PURPOSE To evaluate the feasibility and safety of using phakic intraocular lenses (IOLs) to correct high myopia by comparing 3 IOL models: Adatomed, Staar, and Artisan. SETTING La Fe University Hospital, Department of Ophthalmology, and the Fundación Oftalmológica del Mediterráneo, Valencia, Spain. METHODS In this prospective comparative study, a phakic IOL was implanted in 217 highly myopi...

متن کامل

Three-year follow-up of the Artisan phakic intraocular lens for hypermetropia.

PURPOSE We report the postoperative results of the Artisan Hyperopia phakic intraocular lens (IOL; model 203W; Ophtec, Groningen, The Netherlands). DESIGN Prospective, nonrandomized trial. PARTICIPANTS Twenty-six eyes of 13 self-selected patients with refractive error ranging from +3.00 to +11.00 diopters (D). INTERVENTION Patients with hypermetropia were implanted with the Artisan Hypero...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 31 5  شماره 

صفحات  -

تاریخ انتشار 2005