Cone beam imaging: is this the ultimate imaging modality?

نویسنده

  • Bernard Koong
چکیده

This review article provides an overview of cone beam (CB) imaging technology and its role in orofacial imaging, including comparison with two-dimensional (2D) radiography and multislice computed tomography (MCT). The radiation dose levels of CB systems are discussed, with reference to those delivered by MCT and common dental 2D views. The large variation in dose levels delivered by CB systems and the importance of using ultra low-dose CB units are emphasized. Low-dose MCT protocols can be used. CB and MCT image quality are compared. CB is an essential technique that all dental and orofacial clinicians must be familiar with. Where ultra low-dose systems and protocols are used, CB imaging should be considered in day-to-day clinical practice. However, CB imaging is not the technique of choice in many clinical scenarios. Rather than replacing other modalities, CB imaging complements intraoral 2D radiography, panoramic radiography, MCT and other techniques including magnetic resonance imaging, ultrasound and nuclear medicine. MCT is a much more powerful and flexible modality and presently remains the technique of choice over CB imaging in many clinical scenarios. All radiologic examinations, including CB and MCT, should be comprehensively evaluated in entirety. The responsibilities and the radiological skill levels of clinicians involved in imaging as well as the associated ethical and medico-legal implications require consideration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Dosimetry of Critical Organs in Maxillofacial Imaging with Cone-beam Computed Tomography

Background: While the benefits of cone-beam computed tomography (CBCT) are well known in maxillofacial imaging, the use of this modality is not risk-free.Objective: The aim of this study was to evaluate the exposure doses received by patients during maxillofacial imaging with CBCT.Methods: Entrance surface dose (ESD) was measured by using thermoluminescent dosimeters (TLDs) attached to the eyes...

متن کامل

مقایسه دقت توموگرافی سه‌بعدی با اشعه مخروطی با توموگرافی کامپیوتری مرسوم در تشخیص بیماری‌های سینوس پارانازال

Background: Paranasal sinus disease is one of the most common problems of patients that refer to ENT centers. Adding to clinical examination imaging plays an important role in diagnosis and treatment. Also the imaging of paranasal sinuses is necessary before surgery. Although computed tomography is the modality of choice for these areas, it has some disadvantages which the most important one is...

متن کامل

Artifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging

Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...

متن کامل

A feasibility study on the use of MV-CBCT images for urgent palliative treatment planning

Introduction: The application of 3D volumetric imaging modalities in treatment planning of radiation therapy can provide more precisely define tumor localization, and computed tomography (CT) is the most common accepted method for treatment planning. Given the lack of a CT scanner stationed in all radiotherapy departments and equipping most of the medical linear accelerators wi...

متن کامل

Cone Beam Computed Tomography Imaging of Periodontal Bone

Ashok Balasundaram: Cone beam Computed Tomography imaging of periodontal bone (Under the direction of Dr. André Mol) Cone beam computed tomography (CBCT) is a low-dose, low-cost three dimensional imaging modality used for several oral and maxillofacial applications. This project evaluated the accuracy of Cone-Beam CT imaging to assess periodontal alveolar bone. In Phase I, ground truth measurem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical oral implants research

دوره 21 11  شماره 

صفحات  -

تاریخ انتشار 2010