An experimental survey of metal artefact reduction in computed tomography.
نویسندگان
چکیده
We present a survey of techniques for the reduction of streaking artefacts caused by metallic objects in X-ray Computed Tomography (CT) images. A comprehensive review of the existing state-of-the-art Metal Artefact Reduction (MAR) techniques, drawn predominantly from the medical CT literature, is supported by an experimental comparison of twelve MAR techniques. The experimentation is grounded in an evaluation based on a standard scientific comparison protocol for MAR methods, using a software generated medical phantom image as well as a clinical CT scan. The experimentation is extended by considering novel applications of CT imagery consisting of metal objects in non-tissue surroundings acquired from the aviation security screening domain. We address the shortage of thorough performance analyses in the existing MAR literature by conducting a qualitative as well as quantitative comparative evaluation of the selected techniques. We find that the difficulty in generating accurate priors to be the predominant factor limiting the effectiveness of the state-of-the-art medical MAR techniques when applied to non-medical CT imagery. This study thus extends previous works by: comparing several state-of-the-art MAR techniques; considering both medical and non-medical applications and performing a thorough performance analysis, considering both image quality as well as computational demands.
منابع مشابه
Evaluation of Metal Artifacts in Cone Beam Computed Tomography by Metal Supported Porcelain Crowns Using Different FOV and Localizations: An In Vitro Study
Introduction: Metal-supported porcelain crowns (MSPC) and bridge restorations may be present in the mouths of patients undergoing CBCT imaging. Artifacts that are caused by these MSPCs may adversely affect image quality. The aim of this study is to determine the effect of different FOV (field of view) and localization in FOV on metal artifacts caused by MSPC. Methods:</...
متن کاملEvaluation of Metal Artifact Reduction software in Computed Tomography
Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...
متن کاملMetal Artefact Reduction by Least-Squares Penalized-Likelihood Reconstruction with a Fast Polychromatic Projection Model
We consider penalized-likelihood reconstruction for X-ray computed tomography of objects that contain small metal structures. To reduce the beam hardening artefacts induced by these structures, we derive the reconstruction algorithm from a projection model that takes into account the photon emission spectrum and nonlinear variation of attenuation to photon energy. This algorithm requires excess...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملMetal artefact reduction for accurate tumour delineation in radiotherapy
BACKGROUND AND PURPOSE Two techniques for metal artefact reduction for computed tomography were studied in order to identify their impact on tumour delineation in radiotherapy. MATERIALS AND METHODS Using specially designed phantoms containing metal implants (dental, spine and hip) as well as patient images, we investigated the impact of two methods for metal artefact reduction on (A) the siz...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of X-ray science and technology
دوره 21 2 شماره
صفحات -
تاریخ انتشار 2013