Reducing Dynamically-induced Deviations for Line Scale Calibration in Non-ideal Measurement Situation
نویسندگان
چکیده
− The paper treats the issue of embedding the traceable length metrology into technological process by performing precise dynamic measurements of line scale in its manufacture line. It addresses the error-related problems specific to line scale calibration in dynamic mode of operation that are caused primarily by dynamic loads. Introducing the dynamic regime of calibration leads to the dynamic calibration error originating due to vibration sources in the structure. This uncertainty contribution should be considered and implicated in the total uncertainty budget. A new 3D finite element model was developed in order to both investigate the influence of dynamical excitations of a long stroke comparator structure and evaluate possible influence of vibrations on geometrical dimensions of the line scale. Both the dynamically induced deviations and current capabilities to carry out line scale calibrations were examined experimentally. The experiments were conducted on the interferometer-controlled comparator setup with a moving microscope that was further developed to reduce the calibration repeatability error.
منابع مشابه
Dose estimation with the calibration of dose-response curve of micronucleus in human peripheral lymphocytes induced by 50MeV proton beams
Background: The purpose of this paper is to establish an easy and reliable biodosimeter protocol to evaluate the biological effects of proton beams. Materials and Methods: Human peripheral blood lymphocytes were irradiated using proton beams (LET: 34.6 keV μm−1), and the chromosome aberrations induced were analyzed using cytokinesis-blocked (CB) micronucleus (MN) assay. To determine th...
متن کاملReal Time Calibration of Strap-down Three-Axis-Magnetometer for Attitude Estimation
Three-axis-magnetometers (TAMs) are widely utilized as a key component of attitude determination subsystems and as such are considered the corner stone of navigation for low Earth orbiting (LEO) space systems. Precise geomagnetic-based navigation demands accurate calibration of the magnetometers. In this regard, a complete online calibration process of TAM is developed in the current research t...
متن کاملMeasurement of oxygen fugacities under reducing conditions: Non-Nernstian behavior of Y2O3-doped zirconia oxygen sensors
A calibration procedure is presented for the use of a Y2O3-stabilized zirconia (YSZ) oxygen sensor in 1 atm gas-mixing furnaces in the temperature range 1200–1500°C and 0–8 orders of magnitude below the iron-wüstite (IW) buffer. Corrections to the Nernst equation were obtained by measuring apparent oxygen fugacities of gases in equilibrium with graphite (equilibrated with pure CO vapor), Cr 1 C...
متن کاملQuantifying and Reducing the DOA Estimation Error Resulting from Antenna Pattern Deviation for Direction-Finding HF Radar
High-frequency (HF) radars are routinely used for remotely sensing ocean surface currents. However, the performance of the most widely used direction-finding HF radar is degraded due to the effect of the inevitable deviations of actual antenna pattern on the direction of arrival (DOA) estimation. In this paper, we quantify the DOA estimation error resulting from the deviation of the actual ante...
متن کاملReducing Measurement Error in Nutrition Assessment: Potential Research Implications for Iran
Self-reported measures of dietary intake are prone to measurement error that may obscure the relationship of diet and disease. This review addresses strategies to decrease errors during collection of dietary data and statistical approaches to deal with measurement issues once the data are collected. Examples from two US studies-- the Women’s Health Initiative (WHI) Dietary Modificat...
متن کامل