Dose from syringe procedures during technetium-99m radiopharmaceutical preparation.
نویسندگان
چکیده
UNLABELLED We examined the dose from 99mTc contained in syringes and shielded vials to assess in detail the dose burdens in a central pharmacy. METHODS Absorbed-dose rates at the end of the plunger of a shielded syringe, when 99mTc is contained either in the syringe or in a shielded vial from which the activity would be drawn, were measured with CaF2 dosimeters. The dose rates also were calculated with a Monte Carlo model. RESULTS When activity was contained in either 3-ml or 10-ml disposable syringes shielded by lead glass, the absorbed-dose rates were 1.35-1.62 mGy hr-1 GBq-1 (5-6 mrad hr-1 mCi-1). When the activity was contained in either a shielded elution or product kit vial, the absorbed-dose rates at the end of the syringe plunger were about 0.40 mGy hr-1 GBq-1 (1.4-1.5 mrad hr-1 mCi-1). These results were reproduced with reasonable accuracy by Monte Carlo simulations. CONCLUSION The dose burden per unit of activity handled from 99mTc in procedures using syringes is likely to be two to five times larger than the dose burden from calibrating generator eluate. The Monte Carlo simulations suggest that lead K x-rays may be responsible for a significant fraction of the total dose to the fingers and hand of the pharmacist when lead-glass syringe shields are used.
منابع مشابه
NUCLEAR PHARMACY Dose from Syringe Procedures During Technetium-99m Radiopharmaceutical Preparation
We examined the dose from mTc contained in syringes and shielded vials to assess in detail the dose burdens in a central pharmacy. Methods: Absorbed-dose rates at the end of the plunger of a shielded syringe, when mTc is contained either in the syringe or in a shielded vial from which the activity would be drawn, were measured with CaF2 dosimeters. The dose rates also were calculated with a Mon...
متن کاملAdsorption of some technetium-99m radiopharmaceuticals onto disposable plastic syringes.
OBJECTIVE The purpose of this study was to determine the adsorption behavior of some widely used, commercially available 99mTc radiopharmaceuticals onto different types of plastic syringes. METHODS Kits were reconstituted with 99mTc-pertechnetate diluted with 0.9% saline to produce maximum radioactive concentrations, as stated by the manufacturers. Aliquots of the solutions were transferred t...
متن کاملThe Feasibility of Thyroid Treatment with 99mTc Radiopharmaceuticals and Stable Iodine as Contrast Agent Using MCNP Simulation Code
Introduction: Nowadays, radioisotopes have a lot of therapeutic and diagnostic applications in nuclear medicine. The technetium-99m radioisotope is widely used in the diagnostic field. The technetium-99m radioisotope is widely used in the diagnostic field. In this study, in order to increase the absorption dose in thyroid cancer cells, the radioactive drug technetium-99m which ...
متن کاملPrediction of the structural and spectral properties for L,L-ethylenedicysteine diethylester (EC) and its complex with Technetium-99m radionuclide
The technetium-99m complex of the L,L-ethylenedicysteine diethylester (EC), of the brain imaging agent, was reported as a good choice for replacement of the renal nuclear medicines like OIH radiopharmaceutical. This present research work studies the structural, electronic and spectral properties of the EC compound and its complex with technetium-99m radionuclide from theoretical insight. All co...
متن کاملAssessment of molybdenum breakthrough levels in molybdenum-99/technetium-99m generators: One year experience at NIMRA Jamshoro Pakistan
Background: Technetium-99m radioisotope is the backbone of any nuclear medicine institute. This radioisotope is acquired by the elution of Molybdenum-99/Technetium-99m generator which emits 141 keV gamma ray and having 6.04 hour half-life. Occasionally the contents of Molybdenum-99 may mix up with elute, which may affect image quality and patients may receive higher doses than recommended. This...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine technology
دوره 26 1 شماره
صفحات -
تاریخ انتشار 1998