Vectors of Cofactors of a Screw Matrix and their Relationship with Reciprocal Screws

نویسندگان

  • Jian S Dai
  • John Rees Jones
چکیده

This paper studies the vectors of cofactors in a screw matrix assembled by n screws and investigates the properties and different arrangements of cofactors. An augmentation screw which is linearly independent of n screws in the screw matrix is proposed and is used to relate the vector of cofactors to a reciprocal screw and subsequently to the reciprocal screw system. The paper proposes a new algebraic procedure to evaluate a reciprocal screw and the subsequent (6-n)-reciprocal screw system. The method is invariant and based upon the cofactors of the screw matrix.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implant Removal Matrix for the Upper Extremity Orthopedic Surgeon

Orthopedic implant removal is a commonly performed procedure. While implant removal can be associated withimproved symptoms, risks of the surgery are notable. Stripped screws, broken and retained hardware, and morbidityassociated with soft tissue compromise during difficult removal are all common. Familiarity with the instruments iscritical to procedure success. The purpose of...

متن کامل

The Jacobian Analysis of a Parallel Manipulator Using the Theory of Reciprocal Screws

In this paper, the theory of reciprocal screws is reviewed. Reciprocal screw systems associated with some frequently used kinematic pairs and chains are developed. Then, the application of reciprocal screw systems for the Jacobian analysis of parallel manipulators is described. The Jacobian and singular conditions of a six-dof parallel manipulator are analyzed.

متن کامل

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

An investigation of tensile strength of Ti6Al4V titanium screw inside femur bone using finite element and experimental tests

The geometric optimization of orthopedic screws can considerably increase their orthopedic efficiency. Due to the high geometric parameters of orthopedic screws, a finite element simulation is an effective tool for analyzing and forecasting the effect of the parameters on the load-bearing capacity of different types of screws and bones. Thus, in the present study, the tensile strength of a typi...

متن کامل

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000