Automated urinalysis. Evaluation of the Sysmex UF-50.

نویسندگان

  • H Okada
  • Y Sakai
  • G Kawabata
  • M Fujisawa
  • S Arakawa
  • Y Hamaguchi
  • S Kamidono
چکیده

We assessed the Sysmex UF-50 for reproducibility of results and carryover rate by performing between- and within-run precision analyses on 315 urine samples, evaluated the feasibility of using the UF-50 to measure urinary cellular and noncellular components by comparing results from the UF-50 with results of manual urinalysis using the Kova system, and performed side-by-side comparison of the within-run reproducibility from the UF-50, the UF-100, and the Kova system. Results from the UF-50 and UF-100 were highly reproducible, and the carryover rate was 0.5% or less for the urinary components. In between-run precision assays, the coefficients of variation for UF-50 results for all cellular components were less than 10%. The agreement (gamma statistics) between values from the UF-50 and the Kova system was excellent for RBC, WBC, and bacterial counts. The cell counts from the UF-50 for RBCs, WBCs, epithelial cells, and bacteria were 52%, 63%, 54%, and 110%, respectively, of those measured by manual urinalysis. The UF-50 performed quantitative analysis in 72 seconds, compared with 330 seconds for manual methods. The UF-50 is suitable for the first screening to detect hematuria, pyuria, and bacteriuria.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Sysmex UF-100 automated urinalysis analyzer.

Urinalysis is a high-volume procedure that currently requires significant labor to examine microscopic sediment. We evaluated the Sysmex UF-100 automated urinalysis analyzer for performing this task. Instrument accuracy was assessed by comparing continuous counts of microscopic elements from the UF-100 with ranges of cells (per low-power field or high-power field) from manual microscopy perform...

متن کامل

Automated flow cytometry compared with an automated dipstick reader for urinalysis.

Recently, the Sysmex UF-100 flow cytometer was developed to automate urinalysis. We compared UF-100 test results with those of an automated dipstick reader. A cross-check of UF-100, dipstick, and microscopic sediment data was performed in 1001 urine samples. Good agreements (P <0.001) were obtained between UF-100 and dipstick data for erythrocytes (r = 0.636) and leukocytes (r = 0.785). Even in...

متن کامل

Automated urinalysis: first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting.

BACKGROUND Automated analysis of insoluble urine components can reduce the workload of conventional microscopic examination of urine sediment and is possibly helpful for standardization. We compared the diagnostic performance of two automated urine sediment analyzers and combined dipstick/automated urine analysis with that of the traditional dipstick/microscopy algorithm. METHODS A total of 3...

متن کامل

Automated flow cytometric analysis of cerebrospinal fluid.

BACKGROUND Recently, the UF-100 (Sysmex Corporation) flow cytometer was developed to automate urinalysis. We evaluated the use of flow cytometry in the analysis of cerebrospinal fluid (CSF). METHODS UF-100 data were correlated with microscopy and biochemical data for 256 CSF samples. Microbiological analysis was performed in 144 suspected cases of meningitis. RESULTS Good agreement was obta...

متن کامل

Detection of significant bacteriuria by automated urinalysis using flow cytometry.

A new flow cytometry-based automated urine analyzer, the UF-50, was evaluated for its ability to screen urine samples for significant bacteriuria. One hundred eighty-six urine specimens from patients attending an outpatient clinic of a university-based hospital were examined. The results obtained with the UF-50 were compared with those obtained by conventional quantitative urine culture. The UF...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of clinical pathology

دوره 115 4  شماره 

صفحات  -

تاریخ انتشار 2001