Ion chromatographic determination of ammonia in air using a sampling tube of porous carbon.

نویسندگان

  • Takashi Asada
  • Kikuo Oikawa
  • Kuniaki Kawata
  • Tsutomu Iyobe
  • Akifumi Yamada
چکیده

The ion chromatographic determination of ammonia in air using a sampling tube of porous carbon carbonized at 500 degrees C was examined. When the mean recovery and the reproducibility for a series of five determinations were examined for 1 and 10 ppm ammonia gases, the mean recovery (n = 5) and the relative standard deviation were 97.0% and 3.5% for 1 ppm and 86.9% and 2.8% for 10 ppm, respectively. Furthermore, the recovery from 10 ppm ammonia gas increased with an increase in the extraction time, and a recovery of 99.7% was obtained for 180 min of extraction time. The mean collection efficiency for 1 and 10 ppm ammonia gas was 102.5% and 96.5%, respectively. The relation between the sampling volume and the peak area was linear, and the linearity was 0.999 of the correlation coefficient. The ammonia gas concentration in an actual goat shed could be determined by this sampling device for a sampling volume of 5 L at a flow rate of 1 L/min; 0.79 ppm of the determination value practically agreed as compare with 0.78 ppm from collection by a boric acid solution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of nitrogen dioxide, sulfur dioxide, ozone, and ammonia in ambient air using the passive sampling method associated with ion chromatographic and potentiometric analyses

Concentrations of nitrogen dioxide (NO(2)), sulfur dioxide (SO(2)), ozone (O(3)), and ammonia (NH(3)) were determined in the ambient air of Al-Ain city over a year using the passive sampling method associated with ion chromatographic and potentiometric detections. IVL samplers were used for collecting nitrogen and sulfur dioxides whereas Ogawa samplers were used for collecting ozone and ammonia...

متن کامل

CO2 Removal from Air in a Countercurrent Rotating Packed Bed, Experimental Determination of Height of Transfer Unit

Carbon dioxide capture is a key issue in climate change mitigation. For decades the removal of carbon dioxide has been an essential step in many industrial processing operations such as the synthesis of ammonia, natural gas purification, and oil refining. In this study, a rotating packed bed has been designed for absorption of carbon dioxide from an air stream. The rotating packed bed is a comp...

متن کامل

Passive Sampling of Aromatic Hydrocarbons Toluene, Xylene and Ethylbenzene Using Activated Carbon Fabric in Ambient Air of Tehran

Background & Objectives: Air pollution is one of the most important environmental problems in large cities. Aromatic hydrocarbons as volatile organic compounds (VOCs) have been listed in Hazardous Air Pollutants (HAPs) by Environmental Protection Agencies (EPA). The aim of this study is Passive sampling and determination of aromatic hydrocarbons (AHs) toluene, xylene and ethylbenzene using ...

متن کامل

Design and Thermodynamic analysis of solar air humidifier

In this paper, the cooling system of the air humidifire, completely powered by solar energy, has been designed and optimized. In the cooling system, instead of conventional compression cooling systems, the ammonia absorption refrigeration system has been used.Its design is done in a way that the performanceof the system has increased remarkably in environments with high temperature. The ammonia...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 2004