Analysis of the comparative workflow and performance characteristics of the VITEK 2 and Phoenix systems.

نویسندگان

  • U Eigner
  • A Schmid
  • U Wild
  • D Bertsch
  • A-M Fahr
چکیده

The VITEK 2 (bioMérieux, Marcy L'Etoile, France) and the Phoenix systems (BD Diagnostic Systems, Sparks, Md.) are automated instruments for rapid organism identification and susceptibility testing. We evaluated the workflow, the time to result, and the performance of identification and susceptibility testing of both instruments. A total of 307 fresh clinical isolates were tested: 141 Enterobacteriaceae, 22 nonfermenters, 93 Staphylococcus spp., and 51 Enterococcus spp. Manipulation time was measured in batches, each with seven isolates, for a total of 39 batches. The mean (+/- standard deviation [SD]) manipulation time per batch was 20.9 +/- 1.8 min for Phoenix and 10.6 +/- 1.0 min for VITEK 2 (P < 0.001). Mean (+/-SD) time to result for all bacterial groups was 727 +/- 162 min for Phoenix and 506 +/- 120 min for VITEK 2 (P < 0.001). Concerning identification, Phoenix and VITEK 2 yielded the same results for nonfermenters (100%), staphylococci (97%), and enterococci (100%). For 140 Enterobacteriaceae strains evaluated, 135 (96%) were correctly identified by Phoenix and 137 (98%) by VITEK 2 (P = 0.72). The overall category agreement for all isolates was 97.0% for both instruments. The minor error rate, major error rate, and very major error rate for all bacterial isolates tested were 3.0, 0.3, and 0.6 and 2.8, 0.2, and 1.7 for Phoenix and VITEK 2, respectively (P values of 0.76, 0.75, and 0.09). The VITEK 2 system required less manual manipulation time and less time than the Phoenix system to yield results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of BD Phoenix AP Workflow with Vitek 2.

The BD Phoenix AP instrument reduced the manual setup time for the Phoenix system by 50%. For batches of 14 organisms, the average manual manipulation time per isolate was 89.5 s for BD Phoenix by the use of the AP instrument and 101 s for Vitek 2 (P<0.001).

متن کامل

Comparative evaluation of the BD Phoenix and VITEK 2 automated instruments for identification of isolates of the Burkholderia cepacia complex.

We evaluated two new automated identification systems, the BD Phoenix (Becton Dickinson) and the VITEK 2 (bioMérieux), for identification of isolates of the Burkholderia cepacia complex (BCC). The test sample included 42 isolates of the highly virulent and epidemic genomovar III, 45 isolates of B. multivorans, and 47 isolates of other members of the BCC. Rates of correct identification by the B...

متن کامل

Evaluation of the Etest ESBL and the BD Phoenix, VITEK 1, and VITEK 2 automated instruments for detection of extended-spectrum beta-lactamases in multiresistant Escherichia coli and Klebsiella spp.

Seventy-four isolates of multiresistant Escherichia coli and Klebsiella spp. recovered during a 3-year period and 17 control strains with genotypically identified beta-lactamases were tested for the production of extended-spectrum beta-lactamases (ESBLs) by using the Etest and the VITEK 1, VITEK 2, and Phoenix automated instruments. The use of the Etest was evaluated by investigating its accura...

متن کامل

Comparative performance assessment of flat plate and evacuated tube collectors for domestic water heating systems in Kerman, Iran

This study represents a year-round energy performance of two solar water heating (SWH) systems with a 4m2 flat plate collector (FPC) and an evacuated tube collector (ETC) operating under the same weather conditions. The energy performance of the two considered systems was compared on a monthly and yearly basis. The obtained results showed that for an annual total solar insolation of ...

متن کامل

Comparative analysis of design/build and design/bid/build project delivery systems in Lebanon

Design/bid/build and design/build are two principal project delivery systems used worldwide. The performance of each project may differ with the type of procurement system used. This study has two aims: firstly, to assess and compare the performance of design/bid/build and design/build projects in Lebanon; secondly, to compare the results with the performance of equivalent systems in the Far Ea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 43 8  شماره 

صفحات  -

تاریخ انتشار 2005