The Effect on Performance of Fabrication Parameter Variations of Thick-Film Screen Printed Silver/Silver Chloride Potentiometric Reference Electrodes

نویسندگان

  • M. Glanc
  • M. Sophocleous
  • J. K. Atkinson
چکیده

Thick-film screen printed silver-silver chloride (Ag/AgCl) reference electrodes have been fabricated and investigated as an alternative to liquid electrolyte Ag/AgCl reference electrodes. The performance of the electrodes was examined with variations of the potassium chloride (KCl) concentration in the final (top) layer of the electrode. Also, different types of binder (glass and polymer) were tested for the underlying Ag/AgCl layer. The addition of another layer on top of the KCl containing salt matrix layer has been found to provide a better stability in varying concentrations of KCl test solutions. The electrodes were found to give a satisfactory performance when tested for stability in different pH solutions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of miniaturised thick-film solid state pH sensors

The performance of novel solid state Thick-Film pH sensors for water quality sampling that are designed for deployment in remote catchment areas is described. These miniaturised screen printed planar pH sensors are an alternative to conventional glass pH electrodes that have many disadvantages such as high-cost, large size, mechanical fragility and limited shape. The approach adopted here for i...

متن کامل

Screen Printed Potentiometric Chloride Sensors

Potentiometric chloride sensors were fabricated by electrochemically chloridizing the surface of screen printed silver electrodes using amperostatic coulometry or asymmetric square wave voltammetry. In the case of coulometric chloridization, the effect of different chloride ion sources was also investigated. The response to chloride ions by each type of sensor was determined by measuring their ...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Alternative strategy for manufacturing of all-solid-state reference electrodes for potentiometry

This paper presents an alternative strategy for manufacturing solid-state reference electrodes based on particles of graphite/silver/silver chloride synthesized by electroless deposition of metallic silver and silver chloride on graphite powder. Two kinds of reference electrodes were manufactured by mixing these particles with epoxy resin and hardener: quasi-reference and all-solid-state contai...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013