Aging Study of RPC’s for the SiD Hcal and Muon System

نویسندگان

  • Changguo Lu
  • Kirk McDonald
  • Jiawen Zhang
چکیده

RPCs built from the new type of Bakelite developed by the BESIII Muon group of IHEP (Beijing) and Gaonengkedi, Inc. (Beijing) for use in the BES III and Daya Bay Muon Systems [1] have achieved acceptable dark noise rates without Linseed oil coating, but aging effects have not been thoroughly studied there is no published report available on this topic. A preliminary study of the Daya Bay Muon System RPCs has indicated a significant aging effect [2], which might be adequate for underground neutrino experiments, but must be understood and mitigated prior to use of this technology for SiD and other future accelerator experiments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative Accuracy of the Simplified Strong Ion Equation to Predict Serum pH in Dogs

BACKGROUND Electrochemical approach to the assessment of acid-base states should provide a better mechanistic explanation of the metabolic component than methods that consider only pH and carbon dioxide. HYPOTHESIS/OBJECTIVES Simplified strong ion equation (SSIE), using published dog-specific values, would predict the measured serum pH of diseased dogs. ANIMALS Ten dogs, hospitalized for va...

متن کامل

Investigating the capability of plastic scintillation detectors in design of a muon radiography system by Geant4 code

Imaging and identifying materials with high atomic numbers and densities, especially radioactive materials, is one of the issues that have been especially considered in recent years. Due to some limitations in conventional and old imaging techniques, finding an alternative method is very important. The cosmic muons with an infinite source are one of the sources that have been recently studied f...

متن کامل

Quality Control of Muon Detectors for BaBar at The Ohio State University

Quality testing was conducted on the LST’s that will replace the existing RPC’s at BaBar. A laboratory was created to adequately test the LST’s. Singles rates, efficiencies, and pulse heights were determined for several tubes. Work was put into learning how to utilize a digital gas flow system.

متن کامل

The PHENIX Muon Trigger Upgrade

The PHENIX muon trigger upgrade adds Level-1 trigger detectors to existing forward muon spectrometers and will enhance the ability of the experiment to pursue a rich program of spin physics in polarized proton collisions at √ s = 500 GeV . The additional muon trigger detectors and Level-1 trigger electronics will allow the experiment to select high momentum muons from the decay of W -bosons and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010