Investigation of photoplethysmographs from the anterior fontanelle of neonates.
نویسندگان
چکیده
Photoplethysmography (PPG) signals have been investigated at a new anatomical site, the anterior fontanelle (ANTF), on the hypothesis that blood supply at this location is preferentially preserved during cases of poor peripheral circulation which might cause the commercial pulse oximeters to fail to estimate accurately arterial blood oxygen saturation (SpO2). Two custom built reflectance PPG sensors have been developed, one for placement on the fontanelle and one on the periphery (foot). A PPG processing system and software were also developed to process the raw PPG signals and to estimate SpO2. A pilot study on sixteen babies, (9 male, 7 female) with a median age of 15.5 d (interquartile range = 46.8 d) and a median weight of 3.15 kg (SD = 0.93 kg), on a neonatal intensive care unit (NICU) has been carried out. PPG signals from the ANTF were of good quality and high signal-to-noise ratio. The amplitudes of the ANTF PPGs were found to be sensitive to changes in amplitude when amplitudes were observed at the reference PPG site. Bland-Altman analysis of the gold standard blood gas analysis reveals that all three sensors are inaccurate at SaO2 < 85-90 %, but the ANTF sensor shows better mean difference than the commercial device.
منابع مشابه
Use of posterior fontanelle in the ultrasound diagnosis of intraventricular/periventricular hemorrhage.
OBJECTIVE To evaluate the use of the posterior fontanelle in premature neonates (< 37 weeks) with a birth weight < 1,500 g in the ultrasound diagnosis of intraventricular/periventricular hemorrhage and to assess whether the use of the anterior fontanelle associated with the posterior fontanelle changes the interrater agreement. METHODS Eighty-five premature neonates were evaluated in this pro...
متن کاملUsefulness of 3D sonography of the central nervous system in neonates and infants in the assessment of intracranial bleeding and its consequences when examined through the anterior fontanelle
Due to the possibility to examine at the patient bedside or incubator, ultrasound imaging of the central nervous system, particularly through the anterior fontanelle, is the most common diagnostic examination performed in neonates and infants with neurological problems. Despite its common application, this method has certain limitations. These limitations are associated with cross-sections of t...
متن کاملUltrasound detection of posterior fossa abnormalities in full-term neonates.
Routine cranial ultrasonography, using the anterior fontanelle as acoustic window enables visualization of the supratentorial brain structures in neonates and young infants. The mastoid fontanelle enables a better view of the infratentorial structures, especially cerebellar hemorrhage in preterm infants. Reports on the usefulness and reliability of cranial ultrasonography using the mastoid font...
متن کاملAwake intubation increases intracranial pressure without affecting cerebral blood flow velocity in infants.
Tracheal intubation is frequently required in neonatal anaesthetic practice. Awake intubation is one method of securing the airway and in certain circumstances, for many anaesthetists, can be preferable to intubation following induction of anaesthesia. Previous studies have inferred that the elevation in anterior fontanelle pressure observed during tracheal intubation in neonates was caused by ...
متن کاملUltrasonic diagnosis of intracranial hemorrhage in high risk neonates.
One hundred and eleven high risk neonates were subjected to (cranial ultrasound (CR-USG) Caranial sonography was performed by 2D realtime scanner with 5 MHz transducer through anterior and posterior fontanelle and temporo-squamal suture. One quarter of these neonates developed intracranial hemorrhage (ICH) within 120 hours of birth. Of them 42.8% neonates recovered completely, 21.4% developed v...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physiological measurement
دوره 35 10 شماره
صفحات -
تاریخ انتشار 2014