Four-Dimensional Real-Time Cine Images of Wrist Joint Kinematics Using Dual Source CT with Minimal Time Increment Scanning
نویسندگان
چکیده
PURPOSE To validate the feasibility of real time kinematography with four-dimensional (4D) dynamic functional wrist joint imaging using dual source CT. MATERIALS AND METHODS Two healthy volunteers performed radioulnar deviation and pronation- supination wrist motions for 10 s and 4 s per cycle in a dual source CT scanner. Scan and reconstruction protocols were set to optimize temporal resolution. Cine images of the reconstructed carpal bone of the moving wrist were recorded. The quality of the images and radiation dosage were evaluated. RESULTS The 4D cine images obtained during 4 s and 10 s of radioulnar motion showed a smooth stream of movement with good quality and little noise or artifact. Images from the pronation-supination motion showed noise with a masked surface contour. The temporal resolution was optimized at 0.28 s. CONCLUSION Using dual source CT, 4D cine images of in vivo kinematics of wrist joint movement were obtained and found to have a shorter scan time, improved temporal resolution and lower radiation dosages compared with those previously reported.
منابع مشابه
Retrospective analysis of artifacts in four-dimensional CT images of 50 abdominal and thoracic radiotherapy patients.
PURPOSE To quantify the type, frequency, and magnitude of artifacts in four-dimensional (4D) CT images acquired using a multislice cine method. METHODS AND MATERIALS Fifty consecutive patients who underwent 4D-CT scanning and radiotherapy for thoracic or abdominal cancers were included in this study. All the 4D-CT scans were performed on the GE multislice PET/CT scanner with the Varian Real-t...
متن کاملLumped-parameter electromyogram-driven musculoskeletal hand model: A potential platform for real-time prosthesis control.
Simple, lumped-parameter musculoskeletal models may be more adaptable and practical for clinical real-time control applications, such as prosthesis control. In this study, we determined whether a lumped-parameter, EMG-driven musculoskeletal model with four muscles could predict wrist and metacarpophalangeal (MCP) joint flexion/extension. Forearm EMG signals and joint kinematics were collected s...
متن کاملDual-time-point FDG-PET/CT Imaging of Temporal Bone Chondroblastoma: A Report of Two Cases
Temporal bone chondroblastoma is an extremely rare benign bone tumor. We encountered two cases showing similar imaging findings on computed tomography (CT), magnetic resonance imaging (MRI), and dual-time-point 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/CT. In both cases, CT images revealed temporal bone defects and sclerotic changes around the tumor. Most parts of the ...
متن کاملSU-F-BRCD-01: A Novel Dual Source Array Tetrahedron Beam Computed Tomography (TBCT) System for Image Guided Radiotherapy.
PURPOSE To design and test the feasibility of a novel dual source array, dual detector array TBCT system which is capable of both volumetric CT imaging as well as real-time stereoscopic x-ray imaging for image guided radiotherapy (IGRT). METHODS Besides producing improved image quality, the geometry of TBCT is also more compact and flexible. It is possible to mount two x-ray source arrays and...
متن کاملFrequent diagnostic errors in cardiac PET/CT due to misregistration of CT attenuation and emission PET images: a definitive analysis of causes, consequences, and corrections.
UNLABELLED Cardiac PET combined with CT is rapidly expanding despite artifactual defects and false-positive results due to misregistration of PET and CT attenuation correction data-the frequency, cause, and correction of which remain undetermined. METHODS Two hundred fifty-nine consecutive patients underwent diagnostic rest-dipyridamole myocardial perfusion PET/CT using (82)Rb, a 16-slice PET...