100 Hz neutron radiography at the BOA beamline using a parabolic focussing guide

نویسندگان

  • Pavel Trtik
  • Manuel Morgano
  • Roman Bentz
  • Eberhard Lehmann
چکیده

The recent developments in scientific complementary metal oxide semiconductor (sCMOS) detector technology allow for imaging of relevant processes with very high temporal resolution with practically negligible readout time. However, it is neutron intensity that limits the high temporal resolution neutron imaging. In order to partially overcome the neutron intensity problem for the high temporal resolution imaging, a parabolic neutron focussing guide was utilized in the test arrangement and placed upstream the detector in such a manner that the focal point of the guide was positioned slightly behind the scintillator screen. In such a test arrangement, the neutron flux can be increased locally by about one order of magnitude, albeit with the reduced spatial resolution due to the increased divergence of the neutron beam. In a pilot test application, an in-situ titration system allowing for a remote delivery of well-defined volumes of liquids onto the sample stage was utilized. The process of droplets of water (H2O) falling into the container filled with heavy water (D2O) and the subsequent process of the interaction and mixing of the two liquids were imaged with temporal resolution of 0.01 s. •Combination of neutron focussing device and use of sCMOS detector allows for very high temporal resolution neutron imaging to be achieved (albeit with reduced spatial resolution and field of view).•In-situ neutron imaging titration device for liquid interaction experiments.•Interaction of otherwise indiscernible liquids (H2O and D2O) visualized using neutron radiography with 0.01 s temporal resolution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of the Performance of a Fundamental Neutron Physics Beamline at the High Flux Isotope Reactor

We study the expected performance of the proposed fundamental neutron physics beamline at the upgraded High Flux Isotope Reactor at Oak Ridge National Laboratory. A curved neutron guide transmits the neutrons from the new cold source into a guide hall. A novel feature of the proposed guide is the use of vertical focussing to increase the flux for experiments that require relatively small cross-...

متن کامل

Implementation of neutron radiography in the MNSR Low Power Research Reactor

Neutron radiography is an unique, advanced and useful non-destructive test method in various industries and researches. Nuclear reactors are powerful and stable neutron sources for the neutron radiography system. In this research, the MNSR research reactor has been used as a neutron source for a neutron radiography system, and its neutron beam parameters have been evaluated. Also, using the dir...

متن کامل

Beamline Improvements to the MInes NEutron Radiography (MINER) Facility

The MInes NEutron Radiography (MINER) facility provides students and researchers at the Colorado School of Mines with the capability to perform neutron imaging at the Geological Survey TRIGA Reactor (GSTR). The current beamline consists of a 1.5 inch innerdiameter aluminum pipe routed from the reactor up to an experiment station in the reactor bay. There are several limitations associated with ...

متن کامل

Neutron Imaging Beamline for Advanced Imaging Applications at Dhruva reactor, India

Neutron radiography has long been used in various scientific investigations and industrial applications that require thermal neutrons for characterization. Different kinds of sources such as radioactive sources, portable and accelerator based neutron generators and nuclear reactors can be used to provide thermal beam of neutrons suited for neutron radiography. Among the different varieties of n...

متن کامل

Radiation Safety Assessment of the New Neutron Radiography System at Tehran Research Reactor

Recently, a new Neutron Radiography (NR) beam line has been designed, constricted, installed and tested based on the use of E-beam tube of Tehran Research Reactor (TRR). Initial tests have been shown that the system can be used for different samples and purposes such as nuclear plates and rods fuels.  For this end the system need a suitable irradiation room which should be installed at the NR b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2016