Reduction of metal streak artifacts in x-ray computed tomography using a transmission maximum a posteriori algorithm
نویسندگان
چکیده
A maximum a posteriori algorithm for reduction of metal streak artifacts in x-ray computed tomography is presented. The algorithm uses a Markov random field smoothness prior and applies increased sampling in the reconstructed image. Good results are obtained for simulations and phantom measurements: streak artifacts are reduced while small, line-shaped details are preserved.
منابع مشابه
Evaluation of Metal Artifact Reduction software in Computed Tomography
Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...
متن کاملMetal artifact reduction in CT using tissue-class modeling and adaptive prefiltering.
High-density objects such as metal prostheses, surgical clips, or dental fillings generate streak-like artifacts in computed tomography images. We present a novel method for metal artifact reduction by in-painting missing information into the corrupted sinogram. The information is provided by a tissue-class model extracted from the distorted image. To this end the image is first adaptively filt...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملStreak Artifact Reduction in X-ray CT by Separation of ROI
Most of commercial computed tomography (CT) system employs filtered back projection (FBP) based algorithm to reconstruct tomographic image. Although FBP originated from an analytical solution, it generates streak artifacts during practical implementation due to interpolation between projection lines. The presence of streak artifacts will result in misinterpretation of tomographic features espec...
متن کاملComparison of metal artifact in digital tomosynthesis and computed tomography for evaluation of phantoms
We compared metal artifact in X-ray digital tomosynthesis (DT) and modern computed tomography (CT) reconstruction to improve the image quality. We compared the images of a prosthetic phantom (titanium) and a contrast-detail phantom obtained by DT using conventional filtered backprojection (FBP), metal artifact reduction (MAR) processing, and simultaneous iterative reconstruction technique (SIRT...