A Track Physics Retrospective
نویسنده
چکیده
Many condensed matter dosimeters and detectors respond to the perspectives of track physics, a parametric model which relates their response to gamma rays to their response to heavy ions through the radial distribution of dose about a heavy ion’s path. Most dosimeters are treated as 1-hit detectors, a classification which includes emulsions, scintillators, TLDs, the Fricke dosimeter, alanine, and some biological substances: enzymes and Eschericia coli, among others. We have discovered many hit detectors. An extended model describes the killing, transformation, and mutation of biological cells after gamma and heavy ion irradiation. A detector is treated as a black box, in which the only relevant information is the nature of the incident radiation and the output response, although, at times, it is convenient to imagine some simple structure. Because the model is parametric it can be global, applying to many detectors. Once a set of numerical parameters is extracted from experimental findings, the equations of the model predict response to all radiation fields whose photon-particle energy spectrum is known. Finally, parameters of the model serve as a test of the validity of mechanistic theories, for these parameters summarize detector response to all ionizing radiations.
منابع مشابه
Quality Assurance of LINAC by Analyzing the Profile of 6-MV and 10-MV Photon Beams Using Star Track Device
Introduction: According to the American Society of Radiation Oncology, all patients receive radiation therapy during their illness, where radiation is delivered by the medical linear accelerator (Linac). The aim of this study was to evaluate the quality assurance (QA) of the Linac in analyzing the used dose profile in the treatment of cancer tumors. Materi...
متن کاملFabrication of Copper and Iron Nano/Micro Structures on Semiconducting Substrate and Their Electrical Characterization
In this paper, we have studied the electrical properties of the randomly distributed metallic (Co and Fe) nano/ micro wires on Silicon substrate. Deposition was carried out potentiostatically into the pores of the track-etch polycarbonate membrane spin coated onto the Si substrate. Spin coated films were irradiated with 150MeV Ni (+11) ions at a fluence of 8E7 ions/cm2, followed by UV irradiati...
متن کاملDynamic MLC Tracking Using 4D Lung Tumor Motion Modelling and EPID Feedback
Background: Respiratory motion causes thoracic movement and reduces targeting accuracy in radiotherapy. Objective: This study proposes an approach to generate a model to track lung tumor motion by controlling dynamic multi-leaf collimators. Material and Methods: All slices which contained tumor were contoured in the 4D-CT images for...
متن کاملMeasurement of Contemporary and Retrospective Radon Concentration in Ramsar Dwellings Using Polycarbonate Detector
The origins of radon gas are the amount of uranium decay in the soil that is released into space and through the interior gaps of buildings. Radon can enter the respiratory system and cause radiation hazards. Recently research has identified Radon as the second leading cause of lung cancer after cigarette smoking. The indoor concentration of Radon progeny is mentioned as an important issue reg...
متن کاملBeam Collimation during Lumbar Spine Radiography: A Retrospective Study
Introduction: Collimating the primary beam to the area of diagnostic interest (ADI) has been strongly recommended as an effective method to reduce patient’s radiation dose and to improve image quality during radiology practice. Lack or inadequate collimation results in excessive radiation dose to patients and deterioration image quality.Objective: To assess the quality of beam collimation dur...
متن کاملIntercomparison of retrospective radon detectors.
We performed both a laboratory and a field intercomparison of two novel glass-based retrospective radon detectors previously used in major radon case-control studies performed in Missouri and Iowa. The new detectors estimate retrospective residential radon exposure from the accumulation of a long-lived radon decay product, (210)Pb, in glass. The detectors use track registration material in dire...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017