Low-dose dexamethasone suppression test in chronic fatigue syndrome and health.

نویسندگان

  • Jens Gaab
  • Dominik Hüster
  • Renate Peisen
  • Veronika Engert
  • Tanja Schad
  • Thomas H Schürmeyer
  • Ulrike Ehlert
چکیده

OBJECTIVE Subtle dysregulations of the hypothalamus-pituitary-adrenal axis in chronic fatigue syndrome have been described. The aim of this study was to examine the negative feedback regulations of the hypothalamus-pituitary-adrenal axis in chronic fatigue syndrome. METHODS In 21 patients with chronic fatigue syndrome and 21 healthy control subjects, awakening and circadian salivary free cortisol profiles were assessed over 2 consecutive days and compared with awakening and circadian salivary free cortisol profiles after administration of 0.5 mg of dexamethasone at 11:00 PM the previous day. RESULTS Patients with chronic fatigue syndrome had normal salivary free cortisol profiles but showed enhanced and prolonged suppression of salivary free cortisol after the administration of 0.5 mg of dexamethasone in comparison to the control subjects. CONCLUSIONS Enhanced negative feedback of the hypothalamus-pituitary-adrenal axis could be a plausible explanation for the previously described alterations in hypothalamus-pituitary-adrenal axis functioning in chronic fatigue syndrome. Because similar changes have been described in stress-related disorders, a putative role of stress in the pathogenesis of the enhanced feedback is possible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Glucocorticoid receptor mediated negative feedback in chronic fatigue syndrome using the low dose (0.5 mg) dexamethasone suppression test.

BACKGROUND Chronic fatigue syndrome (CFS) is associated with hypocortisolism, but it is not yet clear the extent to which enhanced negative feedback may underlie this finding. METHODS We undertook a low-dose dexamethasone (0.5 mg) suppression test in 18 CFS patients and 20 matched, healthy controls. We measured salivary cortisol levels at 0800 h, 1200 h, 1600 h and 2000 h before and after the...

متن کامل

Clinical burnout is not reflected in the cortisol awakening response, the day-curve or the response to a low-dose dexamethasone suppression test.

Burnout is presumed to be the result of chronic stress, and chronic stress is known to affect the HPA-axis. To date, studies on HPA-axis functioning in burnout have showed inconsistent results. In the present study, a large sample (n=74) of clinically diagnosed burnout individuals, mostly on sick-leave, were included and compared with 35 healthy controls. Salivary cortisol was sampled on 2 days...

متن کامل

Combined dexamethasone/corticotropin-releasing factor test in chronic fatigue syndrome.

BACKGROUND Studies of hypothalamic-pituitary-adrenal (HPA) axis function in chronic fatigue syndrome (CFS) point to hypofunction, although there are negative reports. Suggested mechanisms include a reduced hypothalamic or supra-hypothalamic stimulus to the HPA axis and enhanced sensitivity to the negative feedback of glucocorticoids. The aim of the current study was to investigate HPA axis func...

متن کامل

Discrepancies in results of low-and high-dose dexamethasone suppression tests for diagnosing preclinical Cushing's syndrome.

According to the diagnostic criteria for adrenal preclinical Cushing's syndrome (PreCS) established by a group headed by the Ministry of Health, Labor and Welfare (MHLW), low- and high-dose dexamethasone suppression tests (DSTs) must be performed to prove autonomous cortisol secretion, i.e., > or =3 microg/dL serum cortisol following 1-mg DST administration, and > or =1 microg/dL serum cortisol...

متن کامل

Comparison of efficacy between 1 mg overnight dexamethasone suppression test and 2-day low dose dexamethasone suppression test for diagnosis of Cushing's syndrome.

OBJECTIVE To assess the sensitivity and specificity of 1 mg overnight dexamethasone suppression test (ODST) and the 2-day low dose dexamethasone suppression test (LDST) for diagnosis of Cushing's syndrome, and to compare the accuracy of both tests using cutoff value at below 5 microg/dl and at below 1.8 microg/dl. MATERIAL AND METHOD The present study is a retrospective study, from 1971-2007,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Psychosomatic medicine

دوره 64 2  شماره 

صفحات  -

تاریخ انتشار 2002