Applicability of radiocolloids, blue dyes and fluorescent indocyanine green to sentinel node biopsy in melanoma.

نویسندگان

  • Hisashi Uhara
  • Naoya Yamazaki
  • Minoru Takata
  • Yuji Inoue
  • Akihiro Sakakibara
  • Yasuhiro Nakamura
  • Keisuke Suehiro
  • Akifumi Yamamoto
  • Riei Kamo
  • Kosuke Mochida
  • Hideya Takenaka
  • Toshiharu Yamashita
  • Tatsuya Takenouchi
  • Shusuke Yoshikawa
  • Akira Takahashi
  • Jiro Uehara
  • Mikio Kawai
  • Hiroaki Iwata
  • Takafumi Kadono
  • Yoshitaka Kai
  • Shoichi Watanabe
  • Satoru Murata
  • Tetsuya Ikeda
  • Hidekazu Fukamizu
  • Toshihiro Tanaka
  • Naohito Hatta
  • Toshiaki Saida
چکیده

Patients with primary cutaneous melanoma underwent sentinel node (SN) mapping and biopsy at 25 facilities in Japan by the combination of radiocolloid with gamma probe and dye. Technetium-99m ((99m)Tc)-tin colloid, (99m)Tc-phytate, 2% patent blue violet (PBV) and 0.4% indigo carmine were used as tracers. In some hospitals, 0.5% fluorescent indocyanine green, which allows visualization of the SN with an infrared camera, was concomitantly used and examined. A total of 673 patients were enrolled, and 562 cases were eligible. The detection rates of SN were 95.5% (147/154) with the combination of tin colloid and PBV, 98.9% (368/372) with the combination of phytate and PBV, and 97.2% (35/36) with the combination of tin colloid or phytate and indigo carmine. SN was not detected in 12 cases by the combination method, and the primary tumor was in the head and neck in six of those 12 cases. In eight of 526 cases (1.5%), SN was detected by PBV but not by radiocolloid. There were 13 cases (2.5%) in which SN was detected by radiocolloid but not by PBV. In 18 of 36 cases (50%), SN was detected by radiocolloid but not by indigo carmine. Concomitantly used fluorescent indocyanine green detected SN in all of 67 cases. Interference with transcutaneous oximetry by PVB was observed in some cases, although it caused no clinical trouble. Allergic reactions were not reported with any of the tracers. (99m)Tc-tin colloid, (99m)Tc-phytate, PBV and indocyanine green are useful tracers for SN mapping.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of Indocyanine Green for Sentinel Lymph Node Biopsy: Case Series and Methods Comparison

Introduction Sentinel lymph node biopsy is indicated for patients with biopsy-proven thickness melanoma greater than 1.0 mm. Use of lymphoscintigraphy along with vital blue dyes is the gold standard for identifying sentinel lymph nodes intraoperatively. Indocyanine green (ICG) has recently been used as a method of identifying sentinel lymph nodes. We herein describe a case series of patients wh...

متن کامل

Sentinel lymph node biopsy in melanoma patients: An experience with Tc-99m antimony sulfide colloid

  Introduction: Sentinel lymph node biopsy is the standard procedure for lymph node staging in intermediate thickness melanoma. In Iran, this procedure has not been addressed sufficiently. In this study, we report our experience in this area. Methods: Ten consecutive patients with intermediate thickness melanoma where included in our study. 1.5 mCi of Tc-99m antimony...

متن کامل

ICG Fluorescence Technique for the Detection of Sentinel Lymph Nodes in Breast Cancer: Results of a Prospective Open-label Clinical Trial Sentinel-Lymphknoten-Detektion beim Mammakarzinom mittels Fluoreszenztechnik – eine Alternative zum Technetiumverfahren?

Introduction: Detection of sentinel lymph nodes (SLN) is the standard procedure to evaluate axillary lymph node status in breast cancer. In addition to known and established procedures such as the blue dye method and scintigraphy, this study investigated the efficacy of a method based on use of the fluorescent dye indocyanine green (ICG). Patients and Method: A total of 126 women with breast ca...

متن کامل

Added value of the hybrid tracer indocyanine green-Tc-nanocolloid for sentinel node biopsy in a series of patients with different lymphatic drainage patterns

Introduction: Indocyanine green (ICG)-Tc-nanocolloid is a novel hybrid fluorescent radioactive tracer for sentinel node (SN) biopsy. This study has aimed to evaluate the added value of this novel versatile tracer in a series of patients with different malignancies. Material and methods: Twenty patients (with penile carcinoma, oral cavity tumors, melanoma) were consecutively included betweenMarc...

متن کامل

Added value of the hybrid tracer indocyanine green-99mTc-nanocolloid for sentinel node biopsy in a series of patients with different lymphatic drainage patterns.

INTRODUCTION Indocyanine green (ICG)-(99m)Tc-nanocolloid is a novel hybrid fluorescent radioactive tracer for sentinel node (SN) biopsy. This study has aimed to evaluate the added value of this novel versatile tracer in a series of patients with different malignancies. MATERIAL AND METHODS Twenty patients (with penile carcinoma, oral cavity tumors, melanoma) were consecutively included betwee...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of dermatology

دوره 39 4  شماره 

صفحات  -

تاریخ انتشار 2012