Succinobucol-Eluting Stents Increase Neointimal Thickening and Peri-Strut Inflammation in a Porcine Coronary Model

نویسندگان

  • Jonathan Watt
  • Simon Kennedy
  • Christopher McCormick
  • Ejaife O Agbani
  • Allan McPhaden
  • Alexander Mullen
  • Peter Czudaj
  • Boris Behnisch
  • Roger M Wadsworth
  • Keith G Oldroyd
چکیده

OBJECTIVE The aim of this study was to assess the efficacy of stent-based delivery of succinobucol alone and in combination with rapamycin in a porcine coronary model. BACKGROUND Current drugs and polymers used to coat coronary stents remain suboptimal in terms of long term efficacy and safety. Succinobucol is a novel derivative of probucol with improved antioxidant and anti-inflammatory properties. METHODS Polymer-free Yukon stents were coated with 1% succinobucol (SucES), 2% rapamycin (RES), or 1% succinobucol plus 2% rapamycin solutions (SucRES) and compared with a bare metal stent (BMS). RESULTS The in vivo release profile of SucES indicated drug release up to 28 days (60% drug released at 7 days); 41 stents (BMS, n = 11; SucES, n =10; RES, n = 10; SucRES, n = 10) were implanted in the coronary arteries of 17 pigs. After 28 days, mean neointimal thickness was 0.31 ± 0.14 mm for BMS, 0.51 ± 0.14 mm for SucES, 0.19 ± 0.11 mm for RES, and 0.36 ± 0.17 mm for SucRES (P < 0.05 for SucES vs. BMS). SucES increased inflammation and fibrin deposition compared with BMS (P < 0.05), whereas RES reduced inflammation compared with BMS (P < 0.05). CONCLUSION In this model, stent-based delivery of 1% succinobucol using a polymer-free stent platform increased neointimal formation and inflammation following coronary stenting.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Frequency of Vascular Inflammation and Impact on Neointimal Proliferation of Drug Eluting Stents in Porcine Coronary Arteries.

BACKGROUND We aimed to describe the frequency of vascular inflammatory reactions with second generation drug eluting stents (DES) compared to first generation DES, and analyze the impact on inflammation and neointimal proliferation in a porcine coronary model. METHODS A total of 26 stents (7 multi-link VISION, 6 CYPHER, 6 TAXUS and 7 XIENCE V) were deployed in the coronary arteries of 10 dome...

متن کامل

Histological validation of frequency domain optical coherence tomography for the evaluation of neointimal formation after a novel polymer-free sirolimus-eluting stent implantation.

Novel polymer-free drug-eluting stents have been developed to reduce polymer-related adverse events. However, neointimal coverage after polymer-free DES implantation is unclear and validation between optical coherence tomography (OCT) and histology is required. Sixteen polymer-free sirolimus-eluting stents were randomly implanted into coronary arteries of 8 normal swine. OCT and histological me...

متن کامل

Vascular responses to drug-eluting and bare metal stents in diabetic/hypercholesterolemic and nonatherosclerotic porcine coronary arteries.

BACKGROUND Animal models used to gain insight into the vascular response to drug-eluting stents are generally juvenile and nonatherosclerotic, whereas stents are placed in patients with complex atherosclerosis and comorbidities. Hence, models reflecting these complexities are needed to help elucidate the vascular effects of drug-eluting stents. We compared the vascular responses with bare metal...

متن کامل

Nanoporous CREG-Eluting Stent Attenuates In-Stent Neointimal Formation in Porcine Coronary Arteries

BACKGROUND The goal of this study was to evaluate the efficacy of a nanoporous CREG-eluting stent (CREGES) in inhibiting neointimal formation in a porcine coronary model. METHODS In vitro proliferation assays were performed using isolated human endothelial and smooth muscle cells to investigate the cell-specific pharmacokinetic effects of CREG and sirolimus. We implanted CREGES, control sirol...

متن کامل

Intriguing peri-strut low-intensity area detected by optical coherence tomography after coronary stent deployment.

BACKGROUND Although peri-strut low-intensity area (PLIA) is frequently observed on post-stenting optical coherence tomography (OCT) images, the histology associated with PLIA is undocumented. METHODS AND RESULTS The 36 porcine coronary lesions treated with bare-metal (BMS: n=16) or drug-eluting (DES: n=20) stents were assessed by OCT and histology at 28 days. DES showed a significantly higher...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 81  شماره 

صفحات  -

تاریخ انتشار 2013