Accuracy of Percutaneous Lumbosacral Pedicle Screw Placement Using the Oblique Fluoroscopic View Based on Computed Tomography Evaluations
نویسندگان
چکیده
STUDY DESIGN Retrospective. PURPOSE This study aims to investigate the accuracy of the oblique fluoroscopic view, based on preoperative computed tomography (CT) images for accurate placement of lumbosacral percutaneous pedicle screws (PPS). OVERVIEW OF LITERATURE Although PPS misplacement has been reported as one of the main complications in minimally invasive spine surgery, there is no comparative data on the misplacement rate among different fluoroscopic techniques, or comparing such techniques with open procedures. METHODS We retrospectively selected 230 consecutive patients who underwent posterior spinal fusion with a pedicle screw construct for degenerative lumbar disease, and divided them into 3 groups, those who had undergone: minimally invasive percutaneous procedure using biplane (lateral and anterior-posterior views using a single C-arm) fluoroscope views (group M-1), minimally invasive percutaneous procedure using the oblique fluoroscopic view based on preoperative CT (group M-2), and conventional open procedure using a lateral fluoroscopic view (group O: controls). The relative position of the screw to the pedicle was graded for the pedicle breach as no breach, <2 mm, 2-4 mm, or >4 mm. Inaccuracy was calculated and assessed according to the spinal level, direction and neurological deficit. Inter-group radiation exposure was estimated using fluoroscopy time. RESULTS Inaccuracy involved an incline toward L5, causing medial or lateral perforation of pedicles in group M-1, but it was distributed relatively equally throughout multiple levels in groups M-2 and controls. The mean fluoroscopy time/case ranged from 1.6 to 3.9 minutes. CONCLUSIONS Minimally invasive lumbosacral PPS placement using the conventional fluoroscopic technique carries an increased risk of inaccurate screw placement and resultant neurological deficits, compared with that of the open procedure. Inaccuracy tended to be distributed between medial and lateral perforations of the L5 pedicle, as a result of pedicle morphology and the PPS pathway. Oblique fluoroscopic views, based on CT measurement, may allow accurate PPS insertion with a shorter fluoroscopy time.
منابع مشابه
Lumbosacral pedicle screw placement using a fluoroscopic pedicle axis view and a cannulated tapping device
BACKGROUND Pedicle screw insertions are commonly used for posterior fixation to treat various spine disorders. However, the misplacement of pedicle screws can lead to disastrous complications. Inaccurate pedicle screw placement is relatively common even when placement is performed under fluoroscopic control. In order to improve the accuracy of the screw placement, we applied a technique using g...
متن کاملElectromagnetic Navigation in Minimally Invasive Spine Surgery: Results of a Cadaveric Study to Evaluate Percutaneous Pedicle Screw Insertion
BACKGROUND This cadaveric study compared efficacy and safety of an electromagnetic (EM) guidance system versus conventional fluoroscopy for percutaneous pedicle screw fixation. As percutaneous pedicle screw fixation becomes increasingly common in spinal surgery, intraoperative imaging systems that maximize efficiency while minimizing radiation exposure and inaccurate trajectories will be progre...
متن کاملDoes a deep seated L5 vertebra position with respect to the iliac crests affect the accuracy of percutaneous pedicle screw placement at lumbosacral junction?
BACKGROUND Significant prominence of iliac crests with a deep seated L5 vertebra can potentially interfere with the screw trajectory when placing percutaneous pedicle screws (PPS) at the lumbosacral segment. The objective of this study was to investigate the influence of L5 position in relation to the iliac crests on the accuracy of percutaneous placement of lumbosacral pedicle screws. METHOD...
متن کاملUse of a quantitative pedicle screw accuracy system to assess new technology: Initial studies on O-arm navigation and its effect on the learning curve of percutaneous pedicle screw insertion
BACKGROUND A quantitative screw accuracy system is proposed that allows for high-fidelity discrimination between various methods of pedicle screw insertion. Our purpose was to study the utility of a quantitative screw accuracy scoring system to assess new imaging technologies and their effects on the minimally invasive spine learning curve. METHODS By use of a hypothetical "perfect screw," a ...
متن کاملAccuracy Assessment of Freehand Pedicular Screw Placement
Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2016