Fractures of distally-fixed femoral stems after revision arthroplasty.

نویسندگان

  • C A Busch
  • M N Charles
  • C M Haydon
  • R B Bourne
  • C H Rorabeck
  • S J Macdonald
  • R W McCalden
چکیده

We identified five (2.3%) fractures of the stem in a series of 219 revision procedures using a cementless, cylindrical, extensively porous-coated, distally-fixed femoral stem. Factors relating to the patients, the implant and the operations were compared with those with intact stems. Finite-element analysis was performed on two of the fractured implants. Factors associated with fracture of the stem were poor proximal bone support (type III-type IV; p = 0.001), a body mass index > 30; (p = 0.014), a smaller diameter of stem (< 13.5 mm; p = 0.007) and the use of an extended trochanteric osteotomy (ETO 4/5: p = 0.028). Finite-element analysis showed that the highest stresses on the stem occurred adjacent to the site of the fracture. The use of a strut graft wired over an extended trochanteric osteotomy in patients lacking proximal femoral cortical support decreased the stresses on the stem by 48%.We recommend the use of a strut allograft in conjunction with an extended trochanteric osteotomy in patients with poor proximal femoral bone stock.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Periprosthetic femoral fractures treated with a modular distally cemented stem.

PURPOSE To assess the treatment outcome of revision hip arthroplasty for Vancouver type B3 periprosthetic femoral fractures using a modular distally cemented stem. METHODS 22 men and 14 women (37 hips) aged 66 to 79 (mean, 70) years underwent revision hip arthroplasty for Vancouver type B3 periprosthetic femoral fractures. The indication for surgery was periprosthetic fracture with stem loose...

متن کامل

Fracture of Uncemented Revision Femoral Stems in three Arthroplasty Patients: A Case Series with three different brands

INTRODUCTION Fracture of stems in primary total hip arthroplasty is a known complication and has been attributed to varus positioning, excessive weight of the patient, resorption of the femoral calcar and failure of the cement mantle. Fractures in uncemented revision femoral stems are rare and are attributed to reduction in proximal support either in the form of bone loss or an extended trochan...

متن کامل

Use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: A case report

INTRODUCTION The thrust plate hip prosthesis (TPP; Zimmer, Winterthur, Switzerland) is a hip prosthesis that is no longer in production. Few reports have focused on periprosthetic fractures following total hip arthroplasty (THA) with the use of a TPP. PRESENTATION OF CASE We report a 57-year-old woman with a periprosthetic femoral fracture 13 years after THA with the use of a TPP. A plain rad...

متن کامل

Challenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem

The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...

متن کامل

Cement-in-cement stem revision for Vancouver type B periprosthetic femoral fractures after total hip arthroplasty

BACKGROUND AND PURPOSE Revision surgery for periprosthetic femoral fractures around an unstable cemented femoral stem traditionally requires removal of existing cement. We propose a new technique whereby a well-fixed cement mantle can be retained in cases with simple fractures that can be reduced anatomically when a cemented revision is planned. This technique is well established in femoral ste...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 87 10  شماره 

صفحات  -

تاریخ انتشار 2005