Refractive power and biometric properties of the nonhuman primate isolated crystalline lens.

نویسندگان

  • David Borja
  • Fabrice Manns
  • Arthur Ho
  • Noel M Ziebarth
  • Ana Carolina Acosta
  • Esdras Arrieta-Quintera
  • Robert C Augusteyn
  • Jean-Marie Parel
چکیده

Purpose. To characterize the age dependence of shape, refractive power, and refractive index of isolated lenses from nonhuman primates. Methods. Measurements were performed on ex vivo lenses from cynomolgus monkeys (cyno: n = 120; age, 2.7-14.3 years), rhesus monkeys (n = 61; age, 0.7-13.3 years), and hamadryas baboons (baboon: n = 16; age, 1.7-27.3 years). Lens thickness, diameter, and surface curvatures were measured with an optical comparator. Lens refractive power was measured with a custom optical system based on the Scheiner principle. The refractive contributions of the gradient, the surfaces, and the equivalent refractive index were calculated with optical ray-tracing software. The age dependence of the optical and biometric parameters was assessed. Results. Over the measured age range isolated lens thickness decreased (baboon: -0.04, cyno: -0.05, and rhesus: -0.06 mm/y) and equatorial diameter increased (logarithmically for the baboon and rhesus, and linearly for cyno: 0.07 mm/y). The isolated lens surfaces flattened and the corresponding refractive power from the surfaces decreased with age (-0.33, -0.48, and -0.68 D/y). The isolated lens equivalent refractive index decreased (only significant for the baboon, -0.001 D/y), and as a result the total isolated lens refractive power decreased with age (baboon: -1.26, cyno: -0.97, and rhesus: -1.76 D/y). Conclusions. The age-dependent trends in the optical and biometric properties, growth, and aging, of nonhuman primate lenses are similar to those of the pre-presbyopic human lens. As the lens ages, the decrease in refractive contributions from the gradient refractive index causes a rapid age-dependent decrease in maximally accommodated lens refractive power.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of shape and gradient refractive index in the accommodative changes of spherical aberration in nonhuman primate crystalline lenses.

PURPOSE To estimate changes in surface shape and gradient refractive index (GRIN) profile in primate lenses as a function of accommodation. To quantify the contribution of surface shape and GRIN to spherical aberration changes with accommodation. METHODS Crystalline lenses from 15 cynomolgus monkeys were studied in vitro under different levels of accommodation produced by a stretching system....

متن کامل

Biometric, optical and physical changes in the isolated human crystalline lens with age in relation to presbyopia

The biometric, optical and physical properties of 19 pairs of isolated human eye-bank lenses ranging in age from 5 to 96 years were compared. Lens focal length and spherical aberration were measured using a scanning laser apparatus, lens thickness and the lens surface curvatures were measured by digitizing the lens profiles and equivalent refractive indices were calculated for each lens using t...

متن کامل

Refractive index distribution and optical properties of the isolated human lens measured using magnetic resonance imaging (MRI)

Using a non-invasive MRI technique for measuring the refractive index distribution through the crystalline lens, refractive index maps were obtained through 20 intact isolated human lenses (7-82years). Focal length measurements, obtained by simulated light ray propagation through each index map were found to be in agreement with direct measurements performed on a scanning laser apparatus. With ...

متن کامل

Nonhuman Primate Ocular Biometry

PURPOSE To examine ocular growth in nonhuman primates (NHPs) from measurements on ex vivo eyes. METHODS We obtained NHP eyes from animals that had been killed as part of other studies or because of health-related issues. Digital calipers were used to measure the horizontal, vertical, and anteroposterior globe diameters as well as corneal horizontal and vertical diameters of excised globes fro...

متن کامل

Crystalline lens power and refractive error.

PURPOSE To study the relationships between the refractive power of the crystalline lens, overall refractive error of the eye, and degree of nuclear cataract. METHODS All phakic participants of the population-based Central India Eye and Medical Study with an age of 50+ years were included. Calculation of the refractive lens power was based on distance noncycloplegic refractive error, corneal r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 51 4  شماره 

صفحات  -

تاریخ انتشار 2010